AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST
DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note:In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
Body Electrical > Air Conditioner > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
Cooler thermistor (room temperature sensor)
Min.: -6.50°C (-20.30°F)
Max.: 57.25°C (135.05°F)
Actual ambient temperature displayed
Cooler thermistor (room temperature sensor) system malfunction:
When open circuit: -6.50°C (-20.30°F)
When short circuit: 57.25°C (135.05°F)
Ambient Temp Sensor
Thermistor assembly (ambient temperature sensor)
Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed
Thermistor assembly (ambient temperature sensor) system malfunction:
When open circuit: -23.30°C (-9.94°F)
When short circuit: 65.95°C (150.71°F)
Adjusted Ambient Temp
Adjusted ambient temperature
Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
-
Air conditioning amplifier assembly malfunction
Evaporator Fin Thermistor
No. 1 cooler thermistor (evaporator temperature sensor)
Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed
No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
When open circuit: -29.70°C (-21.46°F)
When short circuit: 59.55°C (139.19°F)
Evaporator Target Temp
Evaporator target temperature
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed
No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
When open circuit: -29.70°C (-21.46°F)
When short circuit: 59.55°C (139.19°F)
Solar Sensor (D Side)
Driver side automatic light control sensor
Min.: 0
Max.: 255
Driver side automatic light control sensor value increases as brightness increases
Driver side automatic light control sensor system malfunction
Solar Sensor (P Side)
Front passenger side automatic light control sensor
Min.: 0
Max.: 255
Front passenger side automatic light control sensor value increases as brightness increases
Front passenger side automatic light control sensor system malfunction
Engine Coolant Temp
Engine coolant temperature sensor
Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
SFI systemmal function
CAN communication system malfunction
Set Temperature (D Side)
Driver side set temperature
Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed
Driver side set temperature system malfunction
Set Temperature (P Side)
Front passenger side set temperature
Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed
Front passenger side set temperature system malfunction
Blower Motor Speed Level
Blower motor speed level
Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases
Blower with fan motor sub-assembly system malfunction
Regulator Pressure Sensor
Air conditioner pressure sensor
Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual pressure displayed
Air conditioning system (leaks, blocked)
Air conditioner pressure sensor system
Air Mix Servo Targ Pulse(D)
No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
for RHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
Displayed between 5 and 92 pulse (for LHD)
Displayed between 6 and 93 pulse (for RHD)
No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) system malfunction
Air Mix Servo Actual Pulse(D)
No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
for RHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
Displayed between 5 and 92 pulse (for LHD)
Displayed between 6 and 93 pulse (for RHD)
No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) system malfunction
Air Mix Servo Targ Pulse(P)
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
for RHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
Displayed between 6 and 93 pulse (for LHD)
Displayed between 5 and 92 pulse (for RHD)
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) system malfunction
Air Mix Servo Actual Pulse(P)
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse
Min.: 0
Max.: 255
for LHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
for RHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
Displayed between 6 and 93 pulse (for LHD)
Displayed between 5 and 92 pulse (for RHD)
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) system malfunction
Air Outlet Servo Pulse (D)
No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse
Min.: 0
Max.: 255
FACE: 47 (pulse)
B/L: 37 (pulse)
FOOT: 17 (pulse)
FOOT/DEF: 9 (pulse)
DEF: 5 (pulse)
Displayed between 5 and 47 pulse
No. 1 air conditioning radiator damper servo sub-assembly (mode) system malfunction
Air Outlet Servo Actu Pulse(D)
No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse
Min.: 0
Max.: 255
FACE: 47 (pulse)
B/L: 37 (pulse)
FOOT: 17 (pulse)
FOOT/DEF: 9 (pulse)
DEF: 5 (pulse)
Displayed between 5 and 47 pulse
No. 1 air conditioning radiator damper servo sub-assembly (mode) system malfunction
Air Inlet Damper Targ Pulse
No. 1 blower damper servo sub-assembly target pulse
Min.: 0
Max.: 255
for LHD:
RECIRCULATION: 19 (pulse)
FRESH: 7 (pulse)
for RHD:
RECIRCULATION: 7 (pulse)
FRESH: 19 (pulse)
Displayed between 7 and 19 pulse
No. 1 blower damper servo sub-assembly system malfunction
Air Inlet Damper Actual Pulse
No. 1 blower damper servo sub-assembly actual pulse
Min.: 0
Max.: 255
for LHD:
RECIRCULATION: 19 (pulse)
FRESH: 7 (pulse)
for RHD:
RECIRCULATION: 7 (pulse)
FRESH: 19 (pulse)
Displayed between 7 and 19 pulse
No. 1 blower damper servo sub-assembly system malfunction
Electric Heater Count
Maximum electric heater operation level
Min.: 0
Max.: 3
Maximum possible operation of electric heater displayed
PTC heater system malfunction
Electric Heater Active Level
Actual electric heater operation level
Min.: 0
Max.: 3
Actual operation level of electric heater displayed
PTC heater system malfunction
Compressor Speed
Compressor with motor assembly speed
Min.: 0 rpm
Max.: 65535 rpm
Actual compressor rotation speed displayed
Compressor with motor assembly
Compressor Target Speed
Compressor with motor assembly target speed
Min.: 0 rpm
Max.: 65535 rpm
Compressor target rotation speed displayed
Compressor with motor assembly
Shift Set Temperature
Shift set temperature
2C decr, 1C decr, Normal, 1C incr, 2C incr
Customized value displayed
-
Air Inlet Mode
Air inlet mode
Auto or Manual
Customized value displayed
-
Compressor Mode
Compressor mode
Auto or Manual
Customized value displayed
-
Evaporator Control
Evaporator Control
Auto or Manual
Customized value displayed
-
ECO MODE Cancel
ECO run cancel switch input signal
ON or OFF
Customized value displayed
-
ECO Switch
Combination switch assembly (ECO mode switch)
ON or OFF
ON: Combination switch assembly (ECO mode switch) being turned and held at ECO position
OFF: Combination switch assembly (ECO mode switch) not turned
Combination switch assembly (ECO mode switch) system malfunction
Refrigerant Shortage Check
Refrigerant gas volume check
ON or OFF
Customized value displayed
-
Fan speed increment control
Fan speed increment control
Slow, Normal, Fast
Customized value displayed
-
Foot/DEF Auto Mode
Foot/DEF Auto Mode
ON or OFF
Customized value displayed
-
Foot/DEF Auto Blow Up
Foot/DEF Auto blower speed increase
ON or OFF
Customized value displayed
-
Ambient Temperature Shift
Ambient temperature shift
3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr
Customized value displayed
-
Compressor Drive Check
Compressor drive check
OK or NG
OK: Compressor drives
NG: Compressor does not drive
-
Refrigerant Gas Type
Refrigerant gas type
R134a or 1234yf
Refrigerant gas type displayed
-
Blower Motor Brush Wear Amount
Wear amount of blower motor brush output
Min.: 0 μm
Max.: 65535 μm
Wear amount of blower motor brush displayed
-
Operation Limitation Control History Count (Level1)
History of auxiliary battery voltage drop in the past
Min.: 0
Max.: 255
Number of times auxiliary battery voltage dropped in the past displayed
Counted when voltage drops below the specified level due to over discharge while driving.
Tip:Clear control history after check
Operation Limitation Control History Count (Level2)
History of auxiliary battery voltage drop in the past
Min.: 0
Max.: 255
Number of times auxiliary battery voltage dropped in the past displayed
Counted when voltage drops below the specified level due to over discharge while driving.
Tip:Clear control history after check
Outside Air Mode Auto Switch Function
Switches ON/OFF the function to switch the suction opening to the outside air mode automatically when the power switch is turned off
OFF or ON
Customized value displayed
-
Number of Trouble Codes
Number of trouble codes
Min.: 0
Max.: 255
Number of DTCs displayed
-
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
Body Electrical > Air Conditioner > Active Test
Tester Display
Measurement Item
Control Range
Diagnostic Note
Blower Motor
Blower with fan motor sub-assembly
Min.: 0, Max.: 31
-
Magnetic Clutch Relay
Magnet clutch relay
OFF/ON
Operate with hybrid system on and the vehicle stopped
Defogger Relay (Rear)
Defogger relay (engine room junction block assembly)
OFF/ON
-
Heater Active Level
Quick heater assembly
Min.: 0, Max.: 3
Operate with hybrid system on and the vehicle stopped
Air Mix Servo Targ Pulse(D)
No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse
Min.: 0, Max.: 255
Operates between 5 and 92 pulse (for LHD)
Operates between 6 and 93 pulse (for RHD)
Air Mix Servo Targ Pulse(P)
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse
Min.: 0, Max.: 255
Operates between 6 and 93 pulse (for LHD)
Operates between 5 and 92 pulse (for RHD)
Air Outlet Servo Pulse (D)
No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse
Min.: 0, Max.: 255
Operates between 5 and 47 pulses
Air Inlet Damper Targ Pulse
No. 1 blower damper servo sub-assembly target pulse
Min.: 0, Max.: 255
Operates between 7 and 19 pulses
Powertrain > Engine and ECT > Active Test
Tester Display
Measurement Item
Control Range
Diagnostic Note
Control the Electric Cooling Fan
Control electric cooling fan motor
ON/OFF
Perform this test when the following conditions are met:
Power switch on (IG)
Engine stopped
Shift lever in P