BLIND SPOT MONITOR MAIN SWITCH INSPECTION

  1. INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY)

    1. Measure the resistance according to the value(s) in the table below.

      A011XLBE05
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      11 (B) - 8 (D) Blind spot monitor main switch assembly on (not protruding) Below 1 Ω
      11 (B) - 8 (D) Blind spot monitor main switch assembly off (protruding) 10 kΩ or higher
      Text in Illustration
      *a

      Component without harness connected

      (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

      If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).

    2. Check that the switch illuminates.

      1. Apply auxiliary battery voltage to the blind spot monitor main switch (warning canceling switch assembly) and check that the switch illuminates.

        A011XLBE06
        OK
        Connection Specified Condition

        Auxiliary battery positive (+) → Terminal 10 (ILL+)

        Auxiliary battery negative (-) → Terminal 9 (ILL-)

        Illuminates
        Text in Illustration
        *a

        Component without harness connected

        (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

        If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).

    3. Check that the switch indicator illuminates.

      1. Apply auxiliary battery voltage to the blind spot monitor main switch assembly and check the operation of the switch, as shown in the table below.

        A011XLBE07
        OK
        Connection Switch Condition Specified Condition

        Auxiliary battery positive (+) → Terminal 11 (B)

        Auxiliary battery negative (-) → Terminal 12 (E)

        Blind spot monitor main switch assembly on (not protruding) Indicator Illuminates
        Text in Illustration
        *a

        Component without harness connected

        (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

        If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).