SHIFT LEVER POSITION SENSOR INSPECTION

  1. INSPECT SHIFT LEVER POSITION SENSOR

    1. Measure the resistance according to the value(s) in the table below.

      A011XC3E12
      Standard Resistance
      Tester Connection Shift Lever Position Specified Condition
      8 (+B) - 1 (D) D Below 1 Ω
      Except D 10 kΩ or higher
      8 (+B) - 2 (N) N Below 1 Ω
      Except N 4.2 to 5.2 kΩ
      8 (+B) - 3 (P) P Below 1 Ω
      Except P 10 kΩ or higher
      8 (+B) - 4 (R) R Below 1 Ω
      Except R 10 kΩ or higher
      8 (+B) - 5 (MJ) ALL Below 1 Ω
      8 (+B) - 6 (FD) D or B Below 1 Ω
      Except D and B 10 kΩ or higher
      8 (+B) - 7 (B) B Below 1 Ω
      Except B 10 kΩ or higher
      8 (+B) - 9 (RV) R Below 1 Ω
      Except R 10 kΩ or higher
      Text in Illustration
      *a

      Component without harness connected

      (Shift Lever Position Sensor)

      If the result is not as specified, replace the shift lever position sensor.