SHIFT LEVER INSPECTION

  1. INSPECT LOWER SHIFT LEVER ASSEMBLY

    1. Measure the voltage according to the value(s) in the table below.

      A011VKVE01
      Standard Voltage
      Tester Connection Condition Specified Condition
      5 (IG) - Body ground Power switch on (IG) 11 to 14 V
      Power switch off Below 1 V
      4 (STP) - Body ground Brake pedal depressed 11 to 14 V
      Brake pedal released Below 1 V
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Tech Tips

      Do not disconnect the shift lock control unit assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      A011VKVE02
      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (E) - Body ground Always Below 1 Ω
      Text in Illustration
      *a

      Component with harness connected

      (Shift Lock Control ECU)

      Tech Tips

      Do not disconnect the shift lock control unit assembly connector.

    3. Inspect shift lock solenoid

      1. Disconnect the shift lock solenoid connector.

        A011Z79
      2. Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

        A011XV4E09
        Standard Resistance
        Tester Connection Shift Lever Position Specified Condition
        4 (P) - 3 (E2) P 10 kΩ or higher
        4 (P) - 3 (E2) Other than P Below 1 Ω
        Text in Illustration
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        • If the result is not as specified, replace the shift lock control unit assembly.

        • If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (SLS+) - 2 (SLS-) Always 112 Ω
        • If the result is not as specified, replace the shift lock control unit assembly.

        • If the shift lock does not operate when the power source of the shift lock control unit assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the shift lock control unit assembly.