HYBRID CONTROL SYSTEM, Diagnostic DTC:P3108-536

DTC Code DTC Name
P3108-536 Lost Communication with A/C System Control Module

DESCRIPTION

DTC No. INF Code DTC Detection Condition Trouble Area
P3108 536 A/C inverter malfunction
  • Wire harness or connector

  • Compressor with motor assembly

  • Power management control ECU

WIRING DIAGRAM

A011YMFE05

INSPECTION PROCEDURE

PROCEDURE

  1. CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

    1. Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors Click here.

      A011X3A
      OK
      The connectors are connected securely and there are no contact pressure problems.
    NG
    OK
  2. CHECK CONNECTOR CONNECTION CONDITION (COMPRESSOR WITH MOTOR ASSEMBLY CONNECTOR)

    1. Check the connection of connector E65 of the compressor with motor assembly.

      A011X9QE02
      OK
      The connector is connected securely and there are no contact problems.
    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (COMPRESSOR WITH MOTOR ASSEMBLY POWER SOURCE CIRCUIT)

    1. Disconnect connector E65 from the compressor with motor assembly.

    2. Measure the resistance according to the value(s) in the table below.

      A011YESE23
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      E65-5 (GND) - Body ground Power switch off Below 1 Ω
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Compressor with Motor Assembly)

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E65-6 (IG1) - E65-5 (GND) Power switch on (IG) 11 to 14 V

      Note

      Turning the power switch on (IG) with the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Connect the compressor with motor assembly connector.

    NG
    OK
  4. CHECK DTC OUTPUT (HYBRID CONTROL)

    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (READY).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P3108-536 is output. A
      P3108-536 is not output. B
    5. Turn the power switch off.

    B
    A
  5. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - COMPRESSOR WITH MOTOR ASSEMBLY)

    1. Disconnect connector A38 from the power management control ECU.

    2. Disconnect connector E65 from the compressor with motor assembly.

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      A011VQQE17
      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A38-19 (CLK) - Body ground Power switch on (IG) Below 1 V
      A38-30 (ETI) - Body ground Power switch on (IG) Below 1 V
      A38-31 (ITE) - Body ground Power switch on (IG) Below 1 V
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Front view of wire harness connector

      (to Compressor with Motor Assembly)

      Note

      Turning the power switch on (IG) with the power management control ECU connector and the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A38-19 (CLK) - E65-1 (CLK) Power switch off Below 1 Ω
      A38-30 (ETI) - E65-3 (DOUT) Power switch off Below 1 Ω
      A38-31 (ITE) - E65-2 (DIN) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A38-19 (CLK) or E65-1 (CLK) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-30 (ETI) or E65-3 (DOUT) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-31 (ITE) or E65-2 (DIN) - Body ground and other terminals Power switch off 10 kΩ or higher
    7. Connect the compressor with motor assembly connector.

    8. Connect the power management control ECU connector.

    NG
    OK
  6. CHECK POWER MANAGEMENT CONTROL ECU

    1. Disconnect connector E65 from the compressor with motor assembly.

    2. Measure the resistance according to the value(s) in the table below.

      A011YESE24
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      E65-3 (DOUT) - Body ground Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Compressor with Motor Assembly)

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E65-1 (CLK) - Body ground Power switch on (IG) 11 to 14 V
      E65-2 (DIN) - Body ground Power switch on (IG) 11 to 14 V
      E65-3 (DOUT) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Connect the compressor with motor assembly connector.

    NG
    OK
  7. CHECK COMPRESSOR WITH MOTOR ASSEMBLY

    1. Disconnect connector A38 from the power management control ECU.

    2. Measure the resistance according to the value(s) in the table below.

      A011XFSE21
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A38-19 (CLK) - Body ground Power switch off 10 kΩ or higher
      A38-31 (ITE) - Body ground Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A38-30 (ETI) - Body ground Power switch on (IG) 11 to 14 V
      A38-19 (CLK) - Body ground Power switch on (IG) Below 1 V
      A38-31 (ITE) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Connect the power management control ECU connector.

    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - COMPRESSOR WITH MOTOR ASSEMBLY)

    1. Disconnect connector A38 from the power management control ECU.

    2. Disconnect connector E65 from the compressor with motor assembly.

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      A011VQQE18
      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A38-20 (STB) - Body ground Power switch on (IG) Below 1 V
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Front view of wire harness connector

      (to Compressor with Motor Assembly)

      Note

      Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A38-20 (STB) - E65-4 (STBI) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A38-20 (STB) or E65-4 (STBI) - Body ground and other terminals Power switch off 10 kΩ or higher
    7. Connect the compressor with motor assembly connector.

    8. Connect the power management control ECU connector.

    NG
    OK
  9. CHECK POWER MANAGEMENT CONTROL ECU

    1. Disconnect connector E65 from the compressor with motor assembly.

    2. Measure the resistance according to the value(s) in the table below.

      A011YESE25
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      E65-4 (STBI) - Body ground Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Compressor with Motor Assembly)

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E65-4 (STBI) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the compressor with motor assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Connect the compressor with motor assembly connector.

    NG
    OK
  10. CHECK COMPRESSOR WITH MOTOR ASSEMBLY

    1. Disconnect connector A38 from the power management control ECU.

    2. Measure the resistance according to the value(s) in the table below.

      A011XFSE22
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A38-20 (STB) - Body ground Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A38-20 (STB) - Body ground Power switch on (IG) 11 to 14 V

      Note

      Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Connect the power management control ECU connector.

    NG
    OK