HYBRID CONTROL SYSTEM, Diagnostic DTC:P0343-747

DTC Code DTC Name
P0343-747 Camshaft Position Sensor "A" Circuit High Input

DESCRIPTION

Refer to the description for DTC P0340-886 Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
P0343 747 GI signal is not input for 2 sec. or more while the engine is running.
  • SFI system

  • Inverter with converter assembly

  • ECM

  • Power management control ECU

  • Wire harness or connector

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0340-886 Click here.

INSPECTION PROCEDURE

CAUTION:

  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE

  1. CHECK DTC OUTPUT (ENGINE AND ECT)

    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Engine and ECT/ Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      SFI system DTCs are not output. A
      Any of the following DTCs are output. B
      DTC No. Relevant Diagnosis
      P0340 Camshaft Position Sensor Circuit Malfunction
      P0342 Camshaft Position Sensor "A" Circuit Low Input (Bank 1 or Single Sensor)
      P0343 Camshaft Position Sensor "A" Circuit High Input (Bank 1 or Single Sensor)
    5. Turn the power switch off.

    B
    A
  2. CHECK DTC OUTPUT (HYBRID CONTROL)

    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      None of the following DTCs are output. A
      Any of the following DTCs are output. B
      DTC No. Relevant Diagnosis
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module

      Tech Tips

      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0343-747 may be set due to a malfunction which also causes the DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the power switch off.

    B
    A
  3. CHECK DTC OUTPUT (HYBRID CONTROL)

    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0340-886 is not output. A
      P0340-886 is also output. B
    5. Turn the power switch off.

    B
    A
  4. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      A011XKAE01
      OK
      The connectors are connected securely and there are no contact pressure problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.

    NG
    OK
  5. CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

    1. Check the connector connections and contact pressure of the relevant terminals for the ECM connectors Click here.

      A011XUJ

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      OK
      The connectors are connected securely and there are no contact pressure problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.

    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)

    CAUTION:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector A14 from the inverter with converter assembly.

    3. Disconnect connector A25 from the ECM.

    4. Disconnect connector A38 from the power management control ECU.

    5. Connect the cable to the negative (-) auxiliary battery terminal.

    6. Turn the power switch on (IG).

    7. Measure the voltage according to the value(s) in the table below.

      A011YPWE01
      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A14-1 (GI) - Body ground Power switch on (IG) Below 1 V
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to ECM)

      Note

      Turning the power switch on (IG) with the inverter with converter assembly connector and ECM connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    8. Turn the power switch off.

    9. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A14-1 (GI) - A25-60 (G2O) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A14-1 (GI) or A25-60 (G2O) - Body ground and other terminals Power switch off 10 kΩ or higher
    10. Disconnect the cable from the negative (-) auxiliary battery terminal.

    11. Connect the power management control ECU connector.

    12. Connect the ECM connector.

    13. Connect the inverter with converter assembly connector.

    NG
    OK
  7. CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

    1. Check the connector connections and contact pressure of the relevant terminals for the ECM connectors Click here.

      A011XUJ

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      OK
      The connectors are connected securely and there are no contact pressure problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.

    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)

    CAUTION:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector A14 from the inverter with converter assembly.

    3. Disconnect connector A25 from the ECM.

    4. Disconnect connector A38 from the power management control ECU.

    5. Measure the resistance according to the value(s) in the table below.

      A011YPWE01
      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A14-1 (GI) - A25-60 (G2O) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A14-1 (GI) or A25-60 (G2O) - Body ground and other terminals Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to ECM)

    6. Connect the power management control ECU connector.

    7. Connect the ECM connector.

    8. Connect the inverter with converter assembly connector.

    NG
    OK
  9. CHECK HARNESS AND CONNECTOR (ECM - POWER MANAGEMENT CONTROL ECU)

    CAUTION:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A25 from the ECM.

    3. Disconnect connector A38 from the power management control ECU.

    4. Disconnect the connector A14 from the inverter with converter assembly.

    5. Measure the resistance according to the value(s) in the table below.

      A011XECE01
      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A25-60 (G2O) - A38-16 (GI) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A25-60 (G2O) or A38-16 (GI) - Body ground and other terminals Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      *b

      Rear view of wire harness connector

      (to Power Management Control ECU)

    6. Connect the inverter with converter assembly connector.

    7. Connect the power management control ECU connector.

    8. Connect the ECM connector.

    NG
    OK
  10. CHECK INVERTER WITH CONVERTER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from the inverter with converter assembly.

    3. Measure the resistance according to the value(s) in the table below.

      A011YPZE01
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-1 (GI) - A14-10 (GND1) Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Component without harness connected

      (Inverter with Converter Assembly)

    4. Connect the inverter with converter assembly connector.

    NG
    OK
  11. CHECK POWER MANAGEMENT CONTROL ECU

    1. Disconnect all the connectors from the power management control ECU.

    2. Measure the resistance according to the value(s) in the table below.

      A011Z1XE31
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A38-16 (GI) - I3-6 (E1) Power switch off 10 kΩ or higher
      Text in Illustration
      *a

      Component without harness connected

      (Power Management Control ECU)

    3. Connect the power management control ECU connectors.

    NG
    OK