2AR-FXE COOLING SERVICE DATA

THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 to 11.3 mm (0.394 to 0.445 in.) at 95°C (203°F)
COOLING FAN MOTOR
Item Condition Specified Condition
Cooling fan motor Auxiliary battery voltage applied at 20°C (68°F) 10.6 to 16.6 A
No. 2 cooling fan motor Auxiliary battery voltage applied at 20°C (68°F) 10.6 to 16.6 A
COOLING FAN RELAY
Item Tester Connection Specified Condition
Cooling fan relay 3 - 5

10 kΩor higher

(Battery voltage is not applied between terminals 1 and 2)

3 - 5

Below 1 Ω

(Battery voltage is applied between terminals 1 and 2)

RADIATOR
Item Condition Specified Condition
Radiator cap Standard value (for brand-new cap)

93.3 to 122.7 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18.0 psi)

Minimum standard value (for used cap)

78.5 kPa (0.8 kgf/cm2, 11.4 psi)