DESCRIPTION
The combination meter assembly receives the hazard switch ON signal and controls the operation of the hazard warning lights.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING TECHSTREAM
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Hazard Flasher Switch | Hazard switch signal/ON or OFF | ON: Hazard switch on OFF: Hazard switch off |
- |
| OK |
|---|
| Normal conditions listed above are displayed. |
| NG |
|
INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD SWITCH) Click here |
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD SWITCH)
Remove the air conditioning control assembly Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Air Conditioning Control Assembly (Hazard Switch)) |
| NG |
|
REPLACE AIR CONDITIONING CONTROL ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - COMBINATION METER ASSEMBLY)
Disconnect the I17 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here