AIR CONDITIONING AMPLIFIER ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| I77-1 (IG+) - I77-14 (GND) | B - W-B | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| I77-1 (IG+) - I77-14 (GND) | B - W-B | Power source (IG) | Power switch off | Below 1 V |
| I77-4 (ECOS) - I77-14 (GND) | L - W-B | ECO mode switch (eco switch assembly) signal | Power switch on (IG) ECO mode switch (eco switch assembly): on |
Below 1 V |
| I77-4 (ECOS) - I77-14 (GND) | L - W-B | ECO mode switch (eco switch assembly) signal | Power switch on (IG) ECO mode switch (eco switch assembly): off |
11 to 14 V |
| I77-5 (TAM) - I77-13 (SG-2) | P - GR | Ambient temperature sensor signal | Power switch on (IG) Ambient temperature: 25°C (77°F) |
1.35 to 1.75 V |
| I77-5 (TAM) - I77-13 (SG-2) | P - GR | Ambient temperature sensor signal | Power switch on (IG) Ambient temperature: 40°C (104°F) |
0.9 to 1.2 V |
| I77-6 (TFG) - I77-14 (GND) | B - W-B | Glass temperature signal | Power switch on (IG) Glass temperature: 20°C (68°F) |
2.200 kΩ |
| I77-7 (TNG) - I77-14 (GND) | V - W-B | Glass surroundings temperature signal | Power switch on (IG) Glass surroundings temperature: 20°C (68°F) |
2.200 kΩ |
| I77-9 (PRE) - I77-13 (SG-2) | R - GR | Air conditioning pressure sensor signal | Power switch on (READY) A/C system operating Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.9 kgf/cm2, 439 psi)) |
4.80 V or higher |
| I77-9 (PRE) - I77-13 (SG-2) | R - GR | Air conditioning pressure sensor signal | Power switch on (READY) A/C system operating Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 25 psi)) |
Below 0.50 V |
| I77-9 (PRE) - I77-13 (SG-2) | R - GR | Air conditioning pressure sensor signal | Power switch on (READY) A/C system operating Refrigerant pressure: Normal pressure (less than 3025 kPa (30.9 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi)) |
0.50 to 4.80 V |
| I77-10 (S5-3) - I77-13 (SG-2) | V - GR | Power supply for air conditioning pressure sensor | Power switch on (IG) A/C switch: on |
4.75 to 5.25 V |
| I77-10 (S5-3) - I77-13 (SG-2) | V - GR | Power supply for air conditioning pressure sensor | Power switch on (IG) A/C switch: off |
Below 1 V |
| I77-11 (CANH) - I77-12 (CANL) | V - W | CAN communication system | CAN communication occurring | Pulse generation |
| I77-13 (SG-2) - Body ground | GR - Body ground | Ground for air conditioning pressure sensor, ambient temperature sensor | Always | Below 1 V |
| I77-14 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| I77-15 (PTC1) - I77-14 (GND) | G - W-B | Quick heater operation signal |
|
11 to 14 V |
| I77-16 (PTC2) - I77-14 (GND) | L - W-B | Quick heater operation signal |
|
11 to 14 V |
| I77-21 (B) - I77-14 (GND) | Y - W-B | Power source (Back-up) | Power switch off | 11 to 14 V |
| I77-22 (BLW) - I77-14 (GND) | R - W-B | Blower motor speed control signal | Power switch on (IG) Blower switch: LO |
Pulse generation (See waveform 1) |
| I77-27 (IDH) - I77-14 (GND) | SB - W-B | Inverter with converter assembly current over signal | Power switch on (IG) | 4.75 to 5.25 V |
| I77-28 (RH) - I77-14 (GND) | LG - W-B | Humidity sensor signal | Power switch on (IG) Cabin temperature: 25°C (77°F) Humidity: 40% |
2.09 V |
| I77-28 (RH) - I77-14 (GND) | LG - W-B | Humidity sensor signal | Power switch on (IG) Cabin temperature: 25°C (77°F) Humidity: 60% |
2.81 V |
| I77-29 (TR) - I77-34 (SG-1) | P - LG | Room temperature sensor signal | Power switch on (IG) Cabin temperature: 25°C (77°F) |
1.8 to 2.2 V |
| I77-29 (TR) - I77-34 (SG-1) | P - LG | Room temperature sensor signal | Power switch on (IG) Cabin temperature: 40°C (104°F) |
1.2 to 1.6 V |
| I77-32 (TSP) - I77-14 (GND) | Y - W-B | Solar sensor signal (for front passenger side) | Power switch on (IG) Solar sensor subjected to electric light |
0.8 to 4.3 V |
| I77-32 (TSP) - I77-14 (GND) | Y - W-B | Solar sensor signal (for front passenger side) | Power switch on (IG) Solar sensor covered with a cloth |
Below 0.8 V |
| I77-33 (TSD) - I77-14 (GND) | R - W-B | Solar sensor signal (for driver side) | Power switch on (IG) Solar sensor subjected to electric light |
0.8 to 4.3 V |
| I77-33 (TSD) - I77-14 (GND) | R - W-B | Solar sensor signal (for driver side) | Power switch on (IG) Solar sensor covered with a cloth |
Below 0.8 V |
| I77-34 (SG-1) - Body ground | LG - Body ground | Ground for room temperature sensor | Always | Below 1 V |
| I77-35 (SG-4) - Body ground | W - Body ground | Ground for ECO mode switch (eco switch assembly) | Always | Below 1 V |
| I77-37 (LIN1) - I77-14 (GND) | V - W-B | LIN communication signal | Power switch on (IG) | Pulse generation |
| z1-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 V |
| z1-3 (BUS) - z1-2 (BUS G) | - | BUS IC control signal | Power switch on (IG) | Pulse generation |
| z1-4 (B BUS) - z1-2 (BUS G) | - | Power supply for BUS IC | Power switch off | 11 to 14 V |
| z1-5 (SGA) - Body ground | - | Ground for evaporator temperature sensor | Always | Below 1 V |
| z1-6 (TEA) - z1-5 (SGA) | - | Evaporator temperature sensor signal | Power switch on (IG) Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
| z1-6 (TEA) - z1-5 (SGA) | - | Evaporator temperature sensor signal | Power switch on (IG) Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | I77-22 (BLW) - I77-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Vehicle Condition | Power switch on (IG) Blower switch: LO |
POWER MANAGEMENT CONTROL ECU Click here
INVERTER WITH CONVERTER ASSEMBLY Click here
AIR CONDITIONING CONTROL ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| I56-2 (IG+) - I56-6 (GND) | R - W-B | Power source (IG) | Power switch off | Below 1 V |
| I56-2 (IG+) - I56-6 (GND) | R - W-B | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| I56-6 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
| I56-9 (LIN1) - Body ground | V - Body ground | LIN communication signal | Power switch on (IG) | Pulse generation |
| I56-11 (ILL+) - Body ground | G - Body ground | Illumination signal | Light control switch off | Below 1 V |
| I56-11 (ILL+) - Body ground | G - Body ground | Illumination signal | Light control switch tail or head position | 11 to 14 V |
| I56-15 (ILL-) - Body ground | SB - Body ground | Illumination signal | Light control switch off | Below 1 V |
| I56-15 (ILL-) - Body ground | SB - Body ground | Illumination signal | Light control switch tail or head position | Pulse generation |