AIR CONDITIONING SYSTEM


  1. CONSTRUCTION


    1. A cooler thermistor (room temp. sensor) and room temperature sensor (cooler thermistor)* is used.

    2. The cooler thermistor (room temp. sensor) thermistor uses the air flow volume in the air conditioning unit assembly to pass cabin air past the sensor, detecting the cabin temperature using the internal thermistor and outputting it to the air conditioning amplifier assembly.

    3. The rear room temperature sensor (cooler thermistor) consists of a sensor (resistor) that changes the resistance according to the temperature. The cabin temperature is detected by passing cabin air through the sensor and the cabin temperature information is then output to the network door ECU and sent to the air conditioning amplifier assembly via CAN communication.*


      • *: Models with multi-zone (4-zone) climate control