STARTING SYSTEM


  1. OUTLINE


    1. A planetary reduction type starter assembly is used.

    2. A cranking hold function is used. Once the engine switch is pushed, this function operates the starter until the engine starts.

  2. SPECIFICATION

    Rated Output 2.0 kW
    Rated Voltage 12 V
    Length*1 141.1 mm (5.56 in.)
    Weight 3150 g (6.94 lb)
    Rotation Direction*2 Clockwise

    Tech Tips

    *1: Length from the mounted area to the rear end of the starter assembly.

    *2: Viewed from the pinion side

  3. PRECAUTION


    1. Cranking hold function has the following safety features:


      1. While the engine is running, the starter cannot be operated.

      2. The starter will stop operating once the engine has started, even if the engine switch remains pushed.

      3. Starter operation is limited to 30 seconds to protect the starter motor.