CONSTRUCTION
The blower motor with fan sub-assembly has a built-in blower controller which is controlled by the air conditioning amplifier assembly.
A brushless motor is used for the blower motor with fan sub-assembly. This achieves low noise and better use of space, and enhances characteristics of the blower motor, which enables the blower level to be increased.
Along with the usage of the inside-and-outside dual air layer type air conditioning unit, a dual step type sirocco fan with an integrated upper layer fan and lower layer fan is used for the blower motor with fan sub-assembly.
| *1 | Upper Layer Fan | *2 | Lower Layer Fan |
| *3 | Built-in Blower Controller | - | - |