CONSTRUCTION
The battery sensor (battery state sensor assembly) is installed on the negative (-) auxiliary battery terminal.
To detect the current, a shunt resistor installed inside the battery sensor (battery state sensor assembly) is used to convert and calculate the voltage generated in the shunt resistor due to the auxiliary battery charge and discharge current.
The auxiliary battery temperature is calculated from the resistance value of the thermistor built in the battery sensor (battery state sensor assembly).