OUTLINE
A planetary type starter is used.*1
A reduction type starter is used.*2
A starter control (cranking hold function) is used.*3
*1: Except cold area specification models
*2: Cold area specification models
*3: Models with smart entry and start system
SPECIFICATION
| Model | Except Cold Area Specification Models | Cold Area Specification Models | ||
| Manufacture | DENSO | VALEO | BOSCH | DENSO |
| Type | Planetary Type | Planetary Type | Planetary Type | Reduction Type |
| Rating Output | 2.0 kW | 2.2 kW | 1.9 kW | 2.7 kW |
| Rating Voltage | 12 V | 12 V | 12 V | 12 V |
| Length*1 | 196.1 mm (7.72 in.) | 194.0 mm (7.64 in.) | 224.0 mm (8.82 in.) | 213.5 mm (8.41 in.) |
| Weight | 3550 g (7.83 lb) | 3850 g (8.49 lb) | 4500g (9.92 lb) | 8400 g (18.5 lb) |
| Rotational Direction*2 | Clockwise | Clockwise | Clockwise | Clockwise |
*1: Length from the mounted area to the rear end of the starter
*2: Viewed from pinion side