STARTING SYSTEM


  1. OUTLINE


    1. A planetary reduction type starter is used on except models for cold area.

    2. A conventional reduction type starter is used on the models for cold area.

    3. A starter control (cranking hold function) is used on the models with entry and start system. Once the engine switch is pushed, this control continues to operate the starter until the engine has started.

  2. SPECIFICATION

    Model Except Cold Area Specification Models Cold Area Specification Models
    Manufacturer BOSCH DENSO DENSO
    Rating Output 1.4kw 1.6kW 2.0 kW
    Rating Voltage 12 V 12 V 12 V
    Length*1 201.25mm (7.92 in.) 190.8 mm (7.51 in.) 187.5 mm (7.38 in.)
    Weight 3400 g (7.5 lb) 3350 g (7.4 lb) 4600 g (10.1 lb)
    Rotating Direction*2 Clockwise Clockwise Clockwise

    Tech Tips

    *1: Length from the mounted area to the rear end of the starter.

    *2: Viewed from pinion side.