AIR CONDITIONING SYSTEM


  1. CONSTRUCTION


    1. Front Blower Motor


      1. The blower motor with fan sub-assembly has a built-in blower controller which is controlled by the air conditioning amplifier assembly.

      2. A DC ferrite brushless motor is used for the front blower motor. This achieves low noise and better use of space, and enhances characteristics of the blower motor, which enables the blower level to be increased.

      3. On LHD models, along with the usage of the inside-and-outside dual air layer type air conditioning unit, a dual step type sirocco fan with an integrated upper layer fan and lower layer fan is used for the blower motor with fan sub-assembly.

        Figure 1. LHD Models

        A01IDBRC02
        *a Upper Layer Fan *b Blower Controller Portion
        *c Lower Layer Fan - -

        Figure 2. RHD Models

        A01IDN3C01
        *a Blower Controller Portion - -
    2. Rear Blower Motor


      1. A DC ferrite motor is used for the rear blower motor.

      2. The blower motor control is positioned on the side of the rear cooling unit assembly. The blower motor control receives operation signals from the air conditioning amplifier assembly and controls the blower motor.

        A01IDJUC01
        *1 Rear Blower Motor with Fan Sub-assembly *2 Blower Motor Control