HYBRID BATTERY SYSTEM


  1. CONSTRUCTION


    1. The service plug grip is connected to the middle of the battery module circuit and is used to manually shut off the high-voltage circuit.

    2. The main fuse for the high-voltage circuit is provided inside of the service plug grip.

    3. An interlock switch is provided on the service plug grip. When the grip section is unlocked, the interlock switch is turned off and the hybrid vehicle control ECU shuts off the system main relays. However, to ensure safety, make sure to turn the power switch off before removing the service plug grip.

      Note

      For further details on how to handle the service plug grip and for other safety cautions, refer to the Repair Manual.

      A01CS0AC01
      *1 Service Plug Grip *2 Insulated Glove
      *3 Main Fuse *4 Interlock Switch
      *5 HV Battery - -