CONSTRUCTION
A Global Inner-fin Condenser (GIC) is provided. This condenser has tubes with high-density inner fins, and outer fins which allows the adoption of thinner cores, contributing to the efficiency of cooling performance.
| *1 | Inner Fin Tube | *2 | Outer Fin |
| *3 | Fin Louver | - | - |
| *a | A-A Cross Section | - | - |
The cooler condenser assembly consists of 2 cooling portions: a condensing portion and a super-cooling portion. These portions are integrated with a gas-liquid separator (modulator). This cooler condenser assembly uses a sub-cool cycle that offers excellent heat-exchange performance.
In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.
| *a | Modulator | *b | Cooler Dryer |
| *c | Filter | - | - |
|
Super-cooling Portion | |
Condensing Portion |