OUTLINE
Air Conditioning System
A single zone automatic air conditioning system or dual zone automatic air conditioning system (left and right independent control) is available depending on the model.
A Positive Temperature Coefficient (PTC) heater is provided as an additional heater, depending on the model.
HFC-134a refrigerant is used for the single zone and dual zone air conditioning systems, depending on the model.
SPECIFICATION
Performance
| Item | Specification | |||
|---|---|---|---|---|
| Single | Dual | |||
| Heater | Heater Output | W | 5200 | 5200 |
| Air Flow Volume | m3/h |
330 | 330 | |
| Power Consumption | W | 205*1/ 195*2 | 205 | |
| Cooler | Cooling Capacity | W | 4650 | 4650 |
| Air Flow Volume | m3/h |
475 | 475 | |
| Power Consumption | W | 240 | 250 | |
*1: LHD models
*2: RHD models
Ventilation and Heater Radiator Unit Sub-assembly
| Item | Specification | ||
|---|---|---|---|
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum (SFA)-II | |
| Size: W x H x L | mm (in.) | 201.5 x 150 x 27 (7.9 x 5.9 x 1.1) | |
| Fin Pitch | mm (in.) | 1.8 (0.07) | |
| Blower Motor with Fan Sub-assembly | Motor Type | K70-10.5T*1/K70-10T*2 | |
| Fan Type | Semi Sirocco | ||
| Fan Size: Dia. x H | mm (in.) | 155 x 65 (6.1 x 2.6) | |
*1: Models with single zone automatic air conditioning system
*2: Models with dual zone automatic air conditioning system
Air Conditioning
| Item | Specification | ||
|---|---|---|---|
| Cooler Condenser (Condenser with Receiver Assembly) | Type | Global Inner-fin Condenser (GIC) | |
| Size: W x H x L | mm (in.) | 636 x 293.4 x 22 (25.0 x 11.6 x 0.9) | |
| Fin Pitch | mm (in.) | 2.7 (0.11) | |
| No. 1 Cooler Evaporator Sub-assembly | Type | Revolutionary super-slim Structure (RS) | |
| Size: W x H x L | mm (in.) | 226.1 x 241 x 38 (8.9 x 9.5 x 1.5) | |
| Fin Pitch | mm (in.) | 3.0 (0.12) | |
| Compressor with Motor Assembly | Type | ES14 | |
| Compressor Oil Type | ND11 | ||
| Refrigerant | Type | HFC-134a | |
| Charge Volume | g | 420 to 520 | |
| Clean Air Filter (Air Refiner Element) | Pollen Removal Type | ||
MAIN FEATURES
The air conditioning system has the following features:
| Feature | Outline |
|---|---|
| High Performance |
|
| Lightweight | Bus connectors with built-in communication/driver ICs are used in the air conditioning harness assembly to create a lightweight wire harness design with a reduced number of wires. The use of this type of connector means that pulse pattern type servo motors are used. |
| Compact |
|
| Others | The following parts are used to ensure high cooling or heating performance while realizing a compact and lightweight construction.
|
*1: Models with PTC heater
*2: Models with sub-cool accelerator