SYSTEM CONTROL
Because the engine stop and start ECU operates the electric oil pump for CVT during idle stop, a stable CVT oil pressure is ensured, enabling a smooth vehicle start.
Engine stop and start ECU actuates the electric oil pump for CVT when it receives an engine stop signal and the following condition is met. The electric oil pump for CVT will stop operating when the engine automatically starts and the engine speed exceeds a specified value.
| Shift Position | P | R | N | D | M |
| Brake On (applied) | ○ | - | ○ | ○ | ○ |
| Brake Off (not applied) | ○ | - | ○ | - | - |
○: Operating
-: Idle stop is disabled
| Item | Condition | Remarks |
| CVT Oil Temperature | 25°C to 111°C (77°F to 231.8°F) | Detected from the oil temperature sensor in the CVT |