СИСТЕМА СНИЖЕНИЯ ТОКСИЧНОСТИ ОТРАБОТАВШИХ ГАЗОВ


  1. CONSTRUCTION


    1. An NSR (NOx Storage Reduction) catalytic converter (exhaust manifold converter sub-assembly) is used in the exhaust manifold converter.

    2. The DPF catalytic converter (exhaust manifold converter sub-assembly) is used in the exhaust manifold converter.

    3. The DPF catalyst purifies the PM.

      B0040DNC01
      *1 Exhaust Manifold Converter Sub-assembly - -
      *a NSR Catalytic Converter *b DPF Catalytic Converter
      *c PM *d NOx Storage layer
      *e NOx *f Pt
      B0040CZ Exhaust Gas - -
    4. The H2S sweeper catalytic converter is also introduced to reduce H2S, during sulfur purge.