STARTING SYSTEM


  1. OUTLINE


    1. A PE70 type starter is used on models with the stop and start system.

    2. A PA64S type starter is used on models without the stop and start system.

    3. A PA64L type starter is used on cold area specification models.

    4. The PE70, PA64S and PA64L type starter assemblies are a planetary reduction type starter assemblies.

      A00XR70C01
      *A PE70 Type - -
      *a Length - -
      A00XRBNC01
      *A PA64S Type - -
      *a Length - -
      A00XRDIC01
      *A PA64L Type - -
      *a Length - -
  2. SPECIFICATION

    Starter Type PE70 (Planetary Reduction Type)*1 PA64S (Planetary Reduction Type)*2 PA64L (Planetary Reduction Type)*3
    Length mm (in.) 166.9 (6.57) 121.15 (4.77) 121.15 (4.77)
    Weight g (lb) 3550 (7.83) 2200 (4.85) 2300 (5.07)
    Rated Voltage V 12 12 12
    Rated Output kW 1.6 1.0 1.2
    Rotation Direction (Viewed from pinion side) Clockwise Clockwise Clockwise

    • *1: Models with stop and start system

    • *2: Models without stop and start system

    • *3: Cold area specification models