SFI SYSTEM


  1. FUNCTION


    1. The Variable Valve Timing-intelligent (VVT-i) control is designed to control the exhaust camshaft within a range of 55° respectively (of crankshaft angle) to provide valve timing optimally suited to the engine condition. This improves torque in all speed ranges as well as increasing fuel economy and reducing exhaust emissions.

      A01KV5TE01
    2. The following effects can be achieved due to the advanced angle and retarded angle of the intake and exhaust valves.

      Figure 1. Operation Model Diagram: Upon Starting and Idling

      A01KV52E03
      *1 Exhaust Valve Opening (Advanced Position)
      *2 Intake Valve Opening (Intermediate Position)
      *3 Ensuring Starting Ability

      Figure 2. Operation Model Diagram: At Partial Load

      A01KVCAE02
      *1 Exhaust Valve Opening (Retarded Position)
      *2 Intake Valve Opening (Retarded Position)
      *3 Atkinson Cycle

      Figure 3. Operation Model Diagram: At Partial Load to Heavy Load

      A01KVDXE02
      *1 Intake Valve Opening (Advanced Position)
      *2 Exhaust Valve Opening (Retarded Position)
      *3 Using Internal EGR or Improving Exhaust Ability
    3. The ECM cooperatively controls the throttle valve, VVT-iW, VVT-i and wastegate valve of the turbocharger sub-assembly to achieve a driving condition with optimal fuel economy during normal driving. Also, the ECM controls each actuator in acccordance with the driver's intentions during acceleration to achieve a high torque response.