OUTLINE
The cooling system is a pressurized, forced-circulation type.
A thermostat with a bypass valve is located in the water inlet housing to maintain a suitable temperature in the cooling system.
A cooling fan control system in which the ECM optimally controls cooling fan speed is used. For details, refer to 6AR-FSE Engine Control.
TOYOTA genuine Super Long Life Coolant (SLLC) is used.
SPECIFICATION
Engine Coolant
TOYOTA genuine Super Long Life Coolant (SLLC) is used. The maintenance interval is as shown in the table below:
| Coolant Type | TOYOTA Genuine SLLC or the Following | |
|---|---|---|
| Maintenance Intervals | First Time | 160000 km (100000 miles) |
| Subsequent | Every 80000 km (50000 miles) | |
| Color | Pink | |
Tech Tips
Similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non borate coolant with long-life hybrid organic acid technology. (Coolant with long-life hybrid organic acid technology consists of a combination of low phosphates and organic acids.)
SLLC is pre-mixed (50% coolant and 50% deionized water), and therefore does not need to be diluted.
If LLC (red-colored) is mixed with SLLC (pink-colored), the interval for LLC (every 40000 km (24000 miles) or 24 months whichever comes first) should be used.
Thermostat
| Thermostat Opening Temperature | 80 to 84 °C (176 to 183 °F) |