COOLING SYSTEM


  1. CONSTRUCTION


    1. Engine Water Pump Assembly


      1. An electric engine water pump assembly, which operates in response to ECM signals, regulates the coolant flow volume, thus, the warm-up performance is further enhanced as well as reducing the cooling loss.

        A004VBJE04
        Text in Illustration
        *1 Timing Chain Cover Assembly *2 Engine Water Pump Assembly
        *3

        Water Inlet Housing Assembly

        - Thermostat

        *4 Stator
        *5 Impeller *6 Shaft
        *a Cross Section - -
    2. Cooling Fan


      1. A ring type cooling fan is used to ensure efficient cooling performance and quieter operation.

        A004UQIE03
        Text in Illustration
        *1 Radiator Assembly *2 Cooling Fan Motor
        *3 Cooling Fan - -