AIR CONDITIONING SYSTEM


  1. OUTLINE


    1. Air Conditioning System


      1. The automatic air conditioning uses independent right and left temperature controls.

      2. A quick heater assembly is used. This improves heating performance.

      3. The automatic air conditioning is provided with a partial recirculation system. This improves heating performance.

  2. SPECIFICATION


    1. Performance

      Heater Heater Output 5200 W
      Air Flow Volume

      330 m3/h

      Power Consumption Less than 205 W
      Quick Heater Assembly Heater Output 495 W
      Air Conditioning Cooling Capacity 4650 W
      Air Flow Volume

      475 m3/h

      Power Consumption

      Less than 250 W*1

      Less than 240 W*2


      • *1: Models with automatic air conditioning

      • *2: Models with manual air conditioning

    2. Ventilation and Heater Radiator

      Ventilation and Heater Radiator Heater Radiator Unit Sub-assembly Type Straight Flow Aluminum-II (SFA-II)
      Size W x H x L

      201.5 mm x 150 mm x 27 mm

      (7.9 in. x 5.9 in. x 1.1 in.)

      Fin Pitch 1.8 mm (0.07 in.)
      Blower Assembly Motor Type

      K70-10.5T*1

      K70-10T*2

      Fan Type Semi Sirocco
      Fan Size Dia. x H 155 mm x 65 mm (6.1 in. x 2.6 in.)

      • *1: Models with manual air conditioning

      • *2: Models with automatic air conditioning

    3. Air Conditioning

      Air Conditioning Condenser Assembly Type

      Global Inner-fin Condenser (GIC)*1

      Multi-flow IV (Sub-cool)*2

      Size W x H x L

      600 mm x 357 mm x 11.5 mm*1

      (23.6 in. x 14.0 in. x 0.4 in.)

      600 mm x 376.6 mm x 16mm*2

      (23.6 in. x 14.8 in. x 0.6 in.)

      Fin Pitch

      2.5 mm (0.1 in.)*1

      2.75 mm (0.1 in.)*2

      No. 1 Cooler Evaporator Sub-assembly Type Revolutionary Super-slim Structure (RS)
      Size W x H x L

      226.1 mm x 241 mm x 38 mm

      (7.8 in. x 9.1 in. x 1.5 in.)

      Fin Pitch 3.0 mm (0.12 in.)
      Compressor Assembly Type

      6SES14C*1

      6SEU14C*2

      Pulley Plastic Damper Limiter (DL)
      Refrigerant Type

      HFC-134a (R134a)*3

      HFO-1234yf (R1234yf)*4

      Charge Volume

      450 g +/- 50 g*3

      420 g +/- 30 g*4


      • *1: Except models with 3ZR-FE engine

      • *2: Models with 3ZR-FE engine

      • *3: Models using HFC-134a (R134a) refrigerant

      • *4: Models using HFO-1234yf (R1234yf) refrigerant

  3. MAIN FEATURES


    1. The air conditioning system has the following features:

      Item Feature
      Same for Manual and Automatic

      The following parts are used to ensure high cooling performance while achieving a compact and lightweight construction:


      • Semi-center Location Air Conditioning Unit

      • Revolutionary Super-slim Structure (RS) Evaporator

      • Straight Flow Aluminum-II (SFA-II) Heater Radiator

      • Global Inner-fin Condenser (GIC)*1 or Multi-Flow (MF-IV) Sub-cool Condenser*2

      A bus connector with a built-in IC is used in a lightweight wire harness design to allow for a reduced number of wires.
      Manual Defroster control logic is used to improve defroster performance.
      Automatic Independent left and right temperature controls are used to achieve greater comfort.

      • *1: Except models with 3ZR-FE engine

      • *2: Models with 3ZR-FE engine

  4. PRECAUTION


    1. Precaution for Refrigerant HFO-1234yf (R1234yf)


      1. Always use HFO-1234yf (R1234yf) as the refrigerant.

        CAUTION:


        • Do not charge the system with refrigerant near open flames, as HFO-1234yf (R1234yf) is combustible.

        • When charging the system with refrigerant, make sure the area is well ventilated (especially be careful in areas where the gas can easily accumulate such as under lifts and in garage pits, as the gas is heavier than air).

        • Follow any local regulations regarding combustible gases.

        • Be sure to use a refrigerant recovery unit that is compatible with HFO-1234yf (R1234yf) systems.

        Tech Tips

        The shape of the service port for refrigerant charging has an exclusive design conforming to international standards for HFO-1234yf (R1234yf) to prevent improper refrigerant charging.

    2. Compressor Oil


      1. Always use ND-OIL 12 as the compressor oil.

      2. When parts of the air conditioning system are removed, quickly block off any areas that are exposed to the outside air with plugs, vinyl tape, etc., as the oil used for HFO-1234yf (R1234yf) systems absorbs moisture easily.

      3. Do not allow the compressor oil to spray, as the oil used for HFO-1234yf (R1234yf) systems has harmful effects on acrylic resins.