AIR CONDITIONING SYSTEM


  1. OUTLINE


    1. Air Conditioning System


      1. The automatic air conditioning uses independent right and left temperature controls.

      2. A quick heater assembly is used. This improves heating performance.

      3. The automatic air conditioning is provided with a partial recirculation system. This improves heating performance.

  2. SPECIFICATION


    1. Performance

      Heater Heater Output 5200 W (4472 Kcal/h)
      Air Flow Volume

      330 m3/h

      Power Consumption

      Less than 205 W*1

      Less than 190 W*2

      Less than 170 W*3

      Quick Heater Assembly Heat Output 495 W +/- 15%
      Air Conditioning Cooling Capacity

      5300 W (4558 Kcal/h)*3

      5100 W (4386 Kcal/h)*1, 2

      Air Flow Volume

      480 m3/h*3

      475 m3/h*1, 2

      Power Consumption

      Less than 250 W*1

      Less than 240 W*2

      Less than 200 W*3


      • *1: RHD models with automatic air conditioning

      • *2: Models with manual air conditioning

      • *3: LHD models with automatic air conditioning

    2. Ventilation and Heater Radiator

      Ventilation and Heater Radiator Heater Radiator Unit Sub-assembly Type Straight Flow Aluminum-II (SFA-II)
      Size W x H x L

      201.5 mm x 150 mm x 27 mm

      (7.9 in. x 5.9 in. x1.1 in.)

      Fin Pitch 1.8 mm (0.07 in.)
      Blower Assembly Motor Type

      K70-10.5*1

      K70-10T*2

      Fan Type Semi Sirocco
      Fan Size Dia. x H 155 mm x 65 mm (6.1 in. x 2.6 in.)

      • *1: Models with manual air conditioning

      • *2: Models with automatic air conditioning

    3. Air Conditioning

      Air Conditioning Condenser Assembly Type Multi-flow IV (Sub-cool)
      Size W x H x L

      600 mm x 376.6 mm x 16 mm

      (23.6 in. x 14.8 in. x 0.6 in.)

      Fin Pitch 2.75 mm (0.11 in.)
      No. 1 Cooler Evaporator Sub-assembly Type Revolutionary super slim Structure (RS)
      Size W x H x L

      226.1 mm x 241 mm x 38 mm

      (7.8 in. x 9.1in. x 1.5 in.)

      Fin Pitch 3.0 mm (0.12 in.)
      Compressor Assembly Type 6SEU14C
      Pulley Plastic Damper Limiter (DL)* (without Magnetic Clutch)
      Refrigerant Type R134a
      Charge Volume 440 g +/- 30 g

      • *: Except models with CVT

  3. MAIN FEATURES


    1. The air conditioning system has the following features:

      Item Feature
      Manual and Automatic Common

      The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction:


      • Semi-center Location Air Conditioning Unit

      • Revolutionary super-slim Structure (RS) Evaporator

      • Straight Flow Aluminum-II (SFA-II) Heater Radiator

      • Multi-Flow-IV (MF-IV) Sub-cool Condenser

      A bus connector with a built-in IC is used in a lightweight wire harness design to allow a reduced number of wires.
      Manual Defroster control logic is used to improve defroster performance.
      Automatic Independent left and right temperature controls are used to achieve greater comfort.