AIR CONDITIONING SYSTEM GENERAL


  1. OUTLINE


    1. The automatic air conditioning system uses left and right independent temperature control and neural network control to enhance comfort.

  2. MAJOR DIFFERENCE


    1. The 2013 models have been modified from the 2012 models as shown below:


      1. Automatic recirculation control has been added for electricity conservation and environment protection.

  3. SPECIFICATION


    1. Performance

      Heater Heater Output W 5850
      Air Flow Volume

      m3/h

      380
      Power Consumption W 220
      Cooler Cooling Capacity W 6100
      Air Flow Volume

      m3/h

      530
      Power Consumption W 260
    2. Ventilation and Heater Core

      Heater Radiator Unit Sub-assembly Type Straight Flow Aluminum (SFA) -II
      Size W x H x L mm (in.) 201.5 x 150 x 27 (7.9 x 5.9 x 1.1)
      Fin Pitch mm (in.) 1.5 (0.06)
      Blower with Fan Motor Sub-assembly Motor Type BMM - K70
      Fan Type Semi Sirocco
      Fan Size (Dia. x H) mm (in.) 165 x 70 (6.5 x 2.8)
    3. Air Conditioning

      Cooler Condenser Assembly Type Multi-Flow (MF)-IV
      Size W x H x L mm (in.)

      726 x 261.4 x 22

      (28.6 x 10.3 x 0.9)

      Fin Pitch mm (in.) 2.7 (0.11)
      Compressor with Motor Assembly Type ES27
      Compressor Oil Type ND11
      Refrigerant Type HFC 134a
      Charge Volume g 480 to 580
      Evaporator Type Revolutionary super-slim Structure (RS)
      Size W x H x L mm (in.) 266.3 x 251 x 38 (10.5 x 9.9 x 1.5)
      Fin Pitch mm (in.) 2.6 (0.10)
  4. MAIN FEATURES


    1. The air conditioning system has the following features:

      High Performance
      • Neural network control is used so passengers can control the air conditioning accurately for maximum comfort.

      • The Positive Temperature Coefficient (PTC) heater system is used. This system contains a PTC heater that heats the air that has passed through the heater radiator unit sub-assembly to ensure proper heater performance.

      Lightweight
      • An air conditioning harness assembly with a built-in IC is used in a lightweight wire harness design to allow a reduced number of wires.

      • The use of this connector means that pulse pattern type servo motors are used.

      Others

      The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction.


      • Semi-center Location Air Conditioning Unit

      • Revolutionary Super-slim Structure (RS) Evaporator

      • Straight Flow Aluminum (SFA)-II Heater Radiator Sub-assembly

      • Multi-Flow (MF)-IV Sub-cool Condenser