OUTLINE
Both manual and automatic air conditioning systems are available.
The automatic air conditioning system uses left and right independent temperature control and neural network control to enhance comfort.
SPECIFICATION
Performance
| Heater | Heater Output | W | 5850 |
| Air Flow Volume | m3/h |
380 | |
| Power Consumption | W | 220 | |
| Cooler | Cooling Capacity | W | 6100 |
| Air Flow Volume | m3/h |
530 | |
| Power Consumption | W | 260 |
Ventilation and Heater Core
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum (SFA) -II | |
| Size W x H x L | mm (in.) | 201.5 x 150 x 27 (7.9 x 5.9 x 1.1) | |
| Fin Pitch | mm (in.) | 1.5 (0.06) | |
| Blower with Fan Motor Sub-assembly | Motor Type | BMM - K70 | |
| Fan Type | Semi Sirocco | ||
| Fan Size (Dia. x H) | mm (in.) | 165 x 70 (6.5 x 2.8) | |
Air Conditioning
| Cooler Condenser Assembly | Type | Multi-Flow (MF)-IV | |
| Size W x H x L | mm (in.) | 720 x 370.2 x 16 (28.3 x 14.6 x 0.6) |
|
| Fin Pitch | mm (in.) | 3.15 (0.12) | |
| Compressor (Compressor with Pulley Assembly)*1 (Cooler Compressor Assembly)*2 |
Type | TSE17C*1 TSB17C*2 |
|
| Pulley | Plastic Damper and Limiter (DL)*1 Steel with Magnetic Clutch*2 |
||
| Oil Volume | cc | 100 to 115 | |
| Refrigerant | Type | HFC 134a | |
| Charge Volume | g | 450 to 550 | |
| Evaporator | Type | Revolutionary super-slim Structure (RS) | |
| Size W x H x L | mm (in.) | 266.3 x 251 x 38 (10.5 x 9.9 x 1.5) | |
| Fin Pitch | mm (in.) | 2.6 (0.10) | |
*1: Models with 2AR-FE engine
*2: Models with 2GR-FE engine
MAIN FEATURES
The air conditioning system has the following features:
| High Performance | Manual and Automatic |
|
| Automatic |
|
|
| Lightweight | Manual and Automatic |
|
| Others | Manual and Automatic | The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction.
|