COOLING SYSTEM DETAILS


  1. CONSTRUCTION


    1. Engine Water Pump Assembly


      1. An electric engine water pump assembly, which operates in response to ECM signals, regulates the coolant flow volume, thus, warm-up performance is further enhanced as well as reducing cooling loss.

        A01LPFEE02
        Text in Illustration
        *1 Timing Chain or Belt Cover Sub-assembly *2 Engine Water Pump Assembly
        *3 Water Inlet with Thermostat Sub-assembly *4 Stator
        *5 Impeller *6 Shaft
        *a Cross Section - -
    2. Cooling Fan


      1. A ring type cooling fan is used. In addition, swirl generation is reduced by enlarging the fan feather edges. Therefore, fan noise has been reduced and cooling ability has been optimized.

        A01LPL1E01
        Text in Illustration
        *1 Radiator Assembly *2 Cooling Fan Motor
        *3 Cooling Fan - -