OUTLINE
A manual air conditioning system and automatic air conditioning system are used.
A rear cooler system is used.
The automatic air conditioning is provided with a partial recirculation system, which improves heating performance.
SPECIFICATION
Performance
| Model | Front | Rear | |
|---|---|---|---|
| Heater | Heater Output | 5000 W*1 4950 W*2 |
- |
| Air Flow Volume | 320 m3/h*1 315 m3/h*2 |
- | |
| Power Consumption | 190 W | - | |
| Cooler | Cooling Capacity | 4600 W*1 4700 W*2 |
2830 W |
| Air Flow Volume | 470 m3/h*1 465 m3/h*2 |
260 m3/h |
|
| Power Consumption | 220 W | 180 W | |
*1: TMT made
*2: TMMIN made
Ventilation and Heater Radiator
| Model | Front | Rear | |
|---|---|---|---|
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum-II (SFA-II) | - |
| Size W x H x L |
201.5 mm x 150 mm x 21 mm (7.9 in. x 5.9 in. x 0.8 in.) |
- | |
| Fin Pitch | 1.8 mm (0.07 in.) | - | |
| Blower with Fan Motor Sub-assembly | Motor Type | K70-10.5T | K62F-13.5W |
| Fan Type | Semi Shroud Fan | Semi Shroud Fan | |
| Fan Size Dia. x H |
155 mm x 65 mm (6.1 in. x 2.6 in.) | 150 mm x 75 mm (5.9 in. x 2.9 in.) | |
Air Conditioning
| Model | Front | Rear | |
|---|---|---|---|
| Cooler Condenser Assembly | Type | Multi-Flow-IV (MF-IV) Sub-cool | |
| Size W x H x L |
620 mm x 530.2 mm x 16 mm (24.4 in. x 20.9 in. x 0.6 in.) |
||
| Fin Pitch | 3.55 mm (0.14 in.) | ||
| No. 1 Cooler Evaporator Sub-assembly | Type | Revolutionary Super-slim Structure (RS) | |
| Size W x H x L |
226.1 mm x 241 mm x 38 mm (8.9 in. x 9.5 in. x 1.5 in.) |
118.9 mm x 251 mm x 38 mm (4.7 in. x 9.9 in. x 1.5 in.) |
|
| Fin Pitch | 2.6 mm (0.1 in.) | ||
| Cooler Compressor Assembly | Type | 10S15C | |
| Pulley | Magnetic Clutch | ||
| Refrigerant | Type | R134a | |
| Charge Volume | 720 g | ||
MAIN FEATURES
The air conditioning system has the following features:
| Item | Feature |
|---|---|
| Manual and Automatic Common | The following parts are used to ensure high cooling performance while achieving a compact and lightweight construction:
|
| Automatic | Defroster control logic is used to improve defroster performance. |