COOLING SYSTEM DETAILS


  1. CONSTRUCTION


    1. Water Pump Assembly


      1. The water pump has two volute chambers, and circulates coolant uniformly to the left and right banks of the cylinder block.

        A01J2OKE01
        Text in Illustration
        *1 Timing Chain Cover *2 Water Pump Gasket
        *3 Water Pump *4 Water Pump Rotor
        *a Volute Chamber *b View from Back Side
        *c From Water Inlet Housing *d Cross Section
    2. Fluid Coupling Assembly


      1. A 3-stage linear temperature-controlled fluid coupling assembly is used. This fluid coupling assembly utilizes the characteristics of a bimetal to switch the fluid passages and appropriately control the silicon oil, in order to change the fan speed in three stages: off, middle, and high. The fan speed from middle to high is controlled linearly.

        A01J2V2E01