STARTING SYSTEM


  1. OUTLINE


    1. PA70L type starter is used for models that are not cold area specification models, and models that do not have the stop and start system.

    2. PA70LLGX type starter is used for cold area specification models.

    3. PA70LLGAE type starter is used on models with the stop and start system.

    4. The PA70L, PA70LLGX and PA70LLGAE types are the planetary reduction type starter.

    5. A cranking hold function is used on models with the entry and start system. Once the engine switch (push start switch) is pushed, this function operates the starter until the engine starts.

      A01UWMQE04
      Text in Illustration (PA70L Type:)
      *a Length - -
      A01UW71E02
      Text in Illustration (PA70LLGX Type:)
      *a Length - -
      A01UWM3E04
      Text in Illustration (PA70LLGAE Type:)
      *a Length - -
  2. SPECIFICATION

    Starter Type PA70L (Planetary Reduction Type) PA70LLGX*1 (Planetary Reduction Type) PA70LLGAE*2 (Planetary Reduction Type)
    Length mm (in.) 149.1 (5.87) 154.1 (6.07) 158.6 (6.24)
    Weight g (lb.) 3200 (7.05) 3250 (7.16) 3400 (7.49)
    Rating Voltage V 12
    Rating Output kW 1.6 2.0 1.7
    Rotating Direction (Viewed from pinion side) Clockwise

    • *1: Cold area specification models

    • *2: Models with stop and start system

  3. PRECAUTION


    1. The cranking hold function has the following safety features.


      1. While the engine is running normally, the starter does not operate.

      2. Even if the driver keeps pressing the engine switch (push start switch), the certification ECU (smart key ECU assembly) stops the output of the STAR and ACCD signals when the engine speed becomes higher than 800 rpm. Thus, the starter operation stops and the certification ECU (smart key ECU assembly) energizes the ACC relay.

      3. In case the driver keeps pressing the engine switch (push start switch) and the engine does not start, the certification ECU (smart key ECU assembly) stops the output of the STAR and ACCD signals after 30 seconds have elapsed. Thus, the starter operation stops and the certification ECU (smart key ECU assembly) energizes the ACC relay.

      4. Also, if the certification ECU (smart key ECU assembly) cannot detect a continuous engine speed signal although the starter is operating and this continues for 6 seconds, the certification ECU (smart key ECU assembly) will stop sending out STAR and ACCD signals. As a result, the starter will stop operating and then the certification ECU (smart key ECU assembly) will energize the ACC relay.