FUNCTION
Roof Sunshade System
The roof sunshade system has the following functions:
| Function | Outline |
|---|---|
| Manual Open-and-close | This function operates when the slide roof motor switch is pressed and held for approximately 0.3 seconds or less. |
| One-touch Auto Open-and-close | This function operates when the slide roof motor switch is pressed and held for approximately 0.3 seconds or more. |
| Jam Protection | The jam protection function automatically stops the roof sunshade and moves it open halfway if a foreign object gets jammed in the roof sunshade during close operation. |
Jam Protection Function
To control the jam protection function, the sliding roof control ECU monitors the amount of movement and judges jamming of the roof sunshade based on the pulse signals from Hall IC1, and the moving direction of the roof sunshade from the phase difference between the pulses from Hall IC1 and Hall IC2.
FAIL-SAFE
Roof Sunshade System
The fail-safes for the roof sunshade system are as follows:
| Function | Outline |
|---|---|
| Position Information Malfunction Judgment | When this function determines that a position malfunction has occurred during operation, it makes the position information indefinite and renders the initialization incomplete. |
| Continuous Operation Restriction | If current is applied to the motor for 35 seconds or longer, this function stops the current. |
| Forced Learning Operation | This function unfix the position information and leaves the initialization incomplete as a safeguard against an inability to close the shade completely. |
| Hall IC Failure Judgment | If one of the Hall ICs fails, the system uses the other Hall IC, which is working, to perform only a motor lock judgment. |
| If both Hall ICs fail, the system will perform a manual operation in which the overload reverse operation is prohibited. | |
| Open Circuit Process | If the system is unable to receive communication signals, it will hold the last received data for 120 ms. Then, it will resume the default setting. |
| Manual Close Operation after Stopping due to Open Overload Detection | If the system detects an overload (ordinary load or seized motor) while opening the sunshade, it will stop the shade and perform a manual close operation in which the shade open operation is prohibited. |
| Reset Relearning Function | If the CPU is reset during a shade open or shade close operation, the system will perform this function when the position information becomes usable. |
DIAGNOSIS
If the sliding roof motor malfunctions, a Diagnostic Trouble Code (DTC) is stored in the sliding roof control ECU. The DTC can be read by connecting the intelligent tester II to DLC3. For details, refer to the Repair Manual.