CONSTRUCTION
Water Pump Assembly
An electric water pump, which operates in response to ECM signals, regulates the coolant flow volume, thus, the warm-up performance is further enhanced as well as reducing the cooling loss.
| *1 | Timing Chain Cover Assembly | *2 | Water Pump Assembly |
| *3 |
|
*4 | Stator |
| *5 | Impeller | *6 | Shaft |
| *7 | Cross Section | - | - |
Cooling Fun
A ring type cooling fan is used. In addition, swirl generation is reduced by enlarging the fan feather edges and thus fan noise has been reduced and cooling ability has been optimized.
| *1 | Radiator Assembly | *2 | Cooling Fan Motor |
| *3 | Cooling Fan | *4 | New Prius |
| *5 | Conventional Models | - | - |