OUTLINE
Air Conditioning System
The automatic air conditioning uses independent right and left temperature controls.
A quick heater assembly is used. This improves heating performance.
The automatic air conditioning is provided with a partial recirculation system. This improves heating performance.
Combustion Type Power Heater
Depending on the operating condition, the engine coolant temperature remains low, making it difficult to ensure the proper heating effect. Thus, in order to provide an adequate heating effect, combustion type power heater is provided.
A power heater switch is located in the air conditioning control assembly.
SPECIFICATION
Performance
| Heater | Heater Output | 5200 W (4472 kcal/h) |
| Air Flow Volume | 330 m3/h |
|
| Power Consumption | Less than 205 W*1 Less than 190 W*2 Less than 170 W*3 |
|
| Quick Heater Assembly | Heat Output | 495 W +/- 15% |
| Air Conditioning | Cooling Capacity | 5300 W (4558 kcal/h)*3 5100 W (4386 kcal/h)*1, 2 |
| Air Flow Volume | 480 m3/h*3 475 m3/h*1, 2 |
|
| Power Consumption | Less than 250 W*1 Less than 240 W*2 Less than 200 W*3 |
*1: RHD models with automatic air conditioning
*2: Models with manual air conditioning
*3: LHD models with automatic air conditioning
Ventilation and Heater Radiator
| Ventilation and Heater Radiator | Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum-II (SFA-II) |
| Size W x H x L |
201.5 mm x 150 mm x 27 mm (7.9 in. x 5.9 in. x 1.1 in.) |
||
| Fin Pitch | 1.8 mm (0.07 in.) | ||
| Blower Assembly | Motor Type | K70-10.5T*1 K70-10T*2 |
|
| Fan Type | Semi Sirocco | ||
| Fan Size Dia. x H |
155 mm x 65 mm (6.1 in. x 2.6 in.) |
*1: Models with manual air conditioning
*2: Models with automatic air conditioning
Air Conditioning
| Air Conditioning | Condenser Assembly | Type | Multi-flow IV (Sub-cool) |
| Size W x H x L |
600 mm x 376.6 mm x 16 mm (23.6 in. x 14.8 in. x 0.6 in.) |
||
| Fin Pitch | 2.75 mm (0.11 in.) | ||
| No. 1 Cooler Evaporator Sub-assembly | Type | Revolutionary super-slim Structure (RS) | |
| Size W x H x L |
226.1 mm x 241 mm x 38 mm (7.8 in. x 9.1 in. x 1.5 in.) |
||
| Fin Pitch | 3.0 mm (0.12 in.) | ||
| Compressor Assembly with Pulley | Type | 5SE12C | |
| Pulley | Plastic Damper Limiter (DL) | ||
| Refrigerant | Type | R134a | |
| Charge Volume | 440 g +/- 30 g |
MAIN FEATURES
The air conditioning system has the following features:
| Item | Feature |
|---|---|
| Manual and Automatic Common | The following parts are used to ensure high cooling performance while achieving a compact and lightweight construction:
|
| A bus connector with a built-in IC is used in a lightweight wire harness design to allow a reduced number of wires. | |
| Manual | Defroster control logic is used to improve defroster performance. |
| Automatic | Independent left and right temperature controls are used to achieve greater comfort. |
Combustion Type Power Heater
This heater system provides a combustion type power heater between the engine and the heater radiator unit sub-assembly. Air and fuel are introduced into the heater's combustion chamber, and a glow plug assembly is used to ignite this mixture. By heating the engine coolant that flows around the combustion chamber, this system ensures the heating effect. The system can be activated or deactivated by turning on or off the power heater switch provided on the air conditioning control assembly.