AIR CONDITIONING SYSTEM GENERAL


  1. OUTLINE


    1. For the purpose of improving its heating performance, a recirculation air mixing door that can partially mix the recirculation air while operating in the fresh-air mode has been provided in the heater blower unit.

    2. A compact, lightweight, and highly efficient straight flow (full-path flow) aluminum heater core has been adopted.

    3. A clean air filter, which removes dust, has been provided in the blower unit as standard equipment.

    4. A heater is standard equipment on the model for Europe.

    5. A heater is optional equipment on models for general countries except Singapore.

    6. As on the previous model, a rear heater is offered as an option on the double-cab model for Europe.

    7. The PTC (Positive Temperature Coefficient) heater system is provided as standard equipment for European models only.

    8. The PTC heater is used to improve the heating performance.

      A01KA8X
  2. SPECIFICATION


    1. Performance

      Destination Europe General Countries
      Item Front Rear Front
      Heater Heat Output W 4590 1600 4590
      Air Flow Volume

      m3/h

      285 95 310
      Power Consumption W 170 25 175
      Defroster Air Flow Volume

      m3/h

      - - 310
    2. Ventilation and Heater

      Destination Europe General Countries
      Item Front Rear Front
      Heater Core Type Straight Flow Type U-turn Flow Type Straight Flow Type
      Size: W x H x L mm (in.) 134.3 x 220 x 27 (5.3 x 8.7 x 1.1) 92.7 x 120.4 x 36 (3.6 x 4.7 x 1.4) 134.3 x 220 x 27 (5.3 x 8.7 x 1.1)
      Fin Pitch mm (in.) 1.8 (0.07) 2.8 1.8 (0.07)
      Blower Motor Type T70F11W 50F36D T70F25W
      Fan Size: Dia. x H mm (in.) 140 x 65 (5.5 x 2.6) 115 x 65 (4.5 x 2.6) 140 x 65 (5.5 x 2.6)