AIR CONDITIONING SYSTEM GENERAL


  1. OUTLINE


    1. For the purpose of improving its heating performance, a recirculation air mixing door that can partially mix the recirculation air while operating in the fresh-air mode has been provided in the front heater blower assembly.

    2. A compact, lightweight, and highly efficient straight flow (full-path flow) aluminum heater core (heater radiator unit sub-assembly) has been adopted.

    3. An air filter, which removes dust, has been provided in the front heater blower assembly as standard equipment.

    4. A heater is optional equipment on models for general countries except models for Singapore package.

      A01KA8X
  2. SPECIFICATION


    1. Performance

      Heater Heat Output W 4590
      Air Flow Volume

      m3/h

      310
      Power Consumption W 175
      Defroster Air Flow Volume

      m3/h

      310
    2. Ventilation and Heater

      Heater Core (Heater Radiator Unit Sub-assembly) Type Straight Flow Type
      Size: W x H x L mm (in.) 134.3 x 220 x 27 (5.3 x 8.7 x 1.1)
      Fin Pitch mm (in.) 1.8 (0.07)
      Blower Motor Type T70F25W
      Fan Size: Dia. x H mm (in.) 140 x 65 (5.5 x 2.6)