OUTLINE
For the purpose of improving its heating performance, a recirculation air mixing door that can partially mix the recirculation air while operating in the fresh-air mode has been provided in the heater blower unit.
A compact, lightweight, and highly efficient straight flow (full-path flow) aluminum heater core has been adopted.
A clean air filter, which removes dust, has been provided in the blower unit as standard equipment.
A heater is standard equipment on the model for Australia and Europe.
A heater is optional equipment on models for general countries except Singapore.
As on the previous model, a rear heater is offered as an option on the double-cab model for Europe.
SPECIFICATION
Performance
| Destination | Europe | General Countries | |||
| Item | Front | Rear | Front | ||
| Heater | Heat Output | W | 4590 | 1600 | 4590 |
| Air Flow Volume | m3/h |
285 | 95 | 310 | |
| Power Consumption | W | 170 | 25 | 175 | |
| Defroster | Air Flow Volume | m3/h |
- | - | 310 |
Ventilation and Heater
| Destination | Europe | General Countries | |||
| Item | Front | Rear | Front | ||
| Heater Core | Type | Straight Flow Type | U-turn Flow Type | Straight Flow Type | |
| Size: W x H x L | mm (in.) | 134.3 x 220 x 27 (5.3 x 8.7 x 1.1) | 92.7 x 120.4 x 36 (3.6 x 4.7 x 1.4) | 134.3 x 220 x 27 (5.3 x 8.7 x 1.1) | |
| Fin Pitch | mm (in.) | 1.8 (0.07) | 2.8 | 1.8 (0.07) | |
| Blower | Motor Type | T70F11W | 50F36D | T70F25W | |
| Fan Size: Dia. x H | mm (in.) | 140 x 65 (5.5 x 2.6) | 115 x 65 (4.5 x 2.6) | 140 x 65 (5.5 x 2.6) | |