AIR CONDITIONING SYSTEM GENERAL


  1. OUTLINE


    1. For the purpose of improving its heating performance, a recirculation air mixing door that can partially mix the recirculation air while operating in the fresh-air mode has been provided in the heater blower unit.

    2. A compact, lightweight, and highly efficient straight flow (full-path flow) aluminum heater core has been adopted.

    3. A clean air filter, which removes dust, has been provided in the blower unit as standard equipment.

    4. A heater is standard equipment on the model for Australia and Europe.

    5. A heater is optional equipment on models for general countries except Singapore.

    6. As on the previous model, a rear heater is offered as an option on the double-cab model for Europe.

      A01KA8X
  2. SPECIFICATION


    1. Performance

      Destination Europe General Countries
      Item Front Rear Front
      Heater Heat Output W 4590 1600 4590
      Air Flow Volume

      m3/h

      285 95 310
      Power Consumption W 170 25 175
      Defroster Air Flow Volume

      m3/h

      - - 310
    2. Ventilation and Heater

      Destination Europe General Countries
      Item Front Rear Front
      Heater Core Type Straight Flow Type U-turn Flow Type Straight Flow Type
      Size: W x H x L mm (in.) 134.3 x 220 x 27 (5.3 x 8.7 x 1.1) 92.7 x 120.4 x 36 (3.6 x 4.7 x 1.4) 134.3 x 220 x 27 (5.3 x 8.7 x 1.1)
      Fin Pitch mm (in.) 1.8 (0.07) 2.8 1.8 (0.07)
      Blower Motor Type T70F11W 50F36D T70F25W
      Fan Size: Dia. x H mm (in.) 140 x 65 (5.5 x 2.6) 115 x 65 (4.5 x 2.6) 140 x 65 (5.5 x 2.6)