WHEN REMOVING,INSTALLING,REPAIRING OR REPLACING PARTS PROCEDURES NECESSARY WHEN BATTERY TERMINAL IS DISCONNECTED / RECONNECTED

Refer to the LEXUS Repair Manual for each work procedure.


  1. PROCEDURES NECESSARY WHEN AUXILIARY BATTERY TERMINAL IS DISCONNECTED/RECONNECTED

    Necessary Procedures Effect/Inoperative Function When Necessary Procedures are not Performed
    Memorize steering angle neutral point LKA/LDA system (for Mono camera type)
    Lane control system (for Stereo camera type)
    Parking support brake system*
    Pre-collision system (for Stereo camera type)
    Pre-collision system (for Mono camera type)
    Adaptive high beam system

      Lighting system (EXT)

    • Cornering lights

    Variable gear ratio steering system
    Parking assist monitor system
    Panoramic view monitor system
    Initialize rear door sunshade system Rear door sunshade system
    Initialize power trunk lid system Power trunk lid system

    *: When performing learning using the GTS.

    Note

    After the power switch is turned off, the navigation system requires approximately a minute to record various types of memory and settings. As a result, after turning the power switch off, wait a minute or more before disconnecting the cable from the negative (-) auxiliary battery terminal.

    Waiting Time before Disconnecting Cable from Negative (-) Auxiliary Battery Terminal
    System Name See Procedure
    Vehicle enrolled in telematics system (w/ Telematics Transceiver for G-BOOK) 6 minutes
    Vehicle not enrolled in telematics system (w/ Telematics Transceiver for G-BOOK) 1 minute