QUARTER PANEL CUT AND JOIN REPLACEMENT SECTIONS (SMALL AREAS)

A018MRJ

  1. REMOVAL

    Symbol meaning
    A002667 Remove Weld Points
    A00264B Cut and Join Location
    A00265G Cut Location for Supply Parts
    A018MK9C01
    *a mm (in.) - -
  2. INSTALLATION

    Symbol meaning
    A018MJA Spot Weld
    A00266T Plug Weld
    A002641 Butt Weld
    A00265Q Body Sealer

      INSTALLATION POINT

    1. Inspect the fitting of the related parts around the new parts before welding. This affects the appearance of the finish.

    2. Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)

    3. Before installing a new part, apply body sealer.

      Tech Tips


      • Apply body sealer evenly about 5 mm (0.20 in.) from the flange, avoiding any oozing.

      • Apply body sealer evenly, about 3 to 4 mm (0.12 to 0.16 in.) in diameter.

    4. After welding, apply foamed sealing material to the corresponding parts. (See the painting / coating)

    5. After welding, apply body sealer to the corresponding parts. (See the painting / coating)

    6. After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.

    A018MLQC01
    *1 QUARTER PANEL - -
    *a mm (in.) - -