POWER WINDOW CONTROL SYSTEM INITIALIZATION


  1. INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR [ALL DOORS])

    CAUTION:

    When the door window regulator is reinstalled or replaced, the power window control system must be initialized. Functions such as auto up/down, jam protection and key-off do not operate if initialization is not performed.

    Tech Tips

    When the battery is replaced, it is not necessary to initialize the door window regulator.

    Note


    • When the door window regulator is replaced, DTC B2313 is output. Clear the DTC after initialization.

    • When performing initialization, do not perform any other procedures.

    • After any door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the auto up function is used, due to detection of a value different from the operation learned value of the door glass movement speed.

    • If the initialization is not completed properly, the LIN communication system may have a malfunction Click here.


    1. Connect the battery and turn the ignition switch to ON.

      Tech Tips

      If the jam protection function operates when its operation conditions are not met, disconnect the battery during a power window operation of the appropriate door window regulator.

    2. Fully close the window by fully pulling the power window switch, and hold the switch for 1 second or more after the window is fully closed to reset the glass position.