INSPECT HEATER CONTROL BASE (AIR INLET CONTROL SWITCH)
| *1 | Component without harness connected (Heater Control Base [Air Inlet Control Switch]) |
Disconnect the connector from the heater control base (air inlet control switch).
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Check that the indicator light comes on.
Turn the heater control base (air inlet control switch) to LOCK.
Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 4, and check that the indicator light comes on.
| OK |
|---|
| The indicator light comes on. |
If the result is not as specified, replace the heater control base (air inlet control switch).
INSPECT HEATER CONTROL (BLOWER SWITCH)
| *1 | Component without harness connected (Heater Control [Blower Switch]) |
Disconnect the connector from the heater control (blower switch).
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Check that the indicator light comes on.
Turn the heater control base (air inlet control switch) to LOCK.
Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 4, and check that the indicator light comes on.
| OK |
|---|
| The indicator light comes on. |
If the result is not as specified, replace the heater control (blower switch).
INSPECT NO. 3 HEATER CONTROL
| *1 | w/ PTC Heater |
| *2 | Component without harness connected (No. 3 Heater Control) |
Disconnect the connector from the No. 3 heater control.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
*1: w/ PTC Heater
Check that the indicator light comes on.
Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 4, and check that the indicator light comes on.
| OK |
|---|
| The indicator light comes on. |
If the result is not as specified, replace the No. 3 heater control.