INSPECT COOLER THERMISTOR (SOLAR SENSOR) (for LHD)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *1 | Component without harness connected (Cooler Thermistor [Solar Sensor]) |
Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).
If the result is not as specified, replace the cooler thermistor (solar sensor).
INSPECT COOLER THERMISTOR (SOLAR SENSOR) (for RHD)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *1 | Component without harness connected (Cooler Thermistor [Solar Sensor]) |
Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).
If the result is not as specified, replace the cooler thermistor (solar sensor).