SOLAR SENSOR (for Automatic Air Conditioning System) INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT COOLER THERMISTOR (SOLAR SENSOR) (for LHD)


    1. A01IOBIE02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I1-3 (TSP) - I1-1 (S5) Solar sensor covered with a cloth ∞ Ω
      I1-3 (TSP) - I1-1 (S5) Solar sensor exposed to electric light Except ∞ Ω
      I1-2 (TSD) - I1-1 (S5) Solar sensor covered with a cloth ∞ Ω
      I1-2 (TSD) - I1-1 (S5) Solar sensor exposed to electric light Except ∞ Ω
      Table 1. Text in Illustration
      *1

      Component without harness connected

      (Cooler Thermistor [Solar Sensor])

      Tip:

      Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).

      If the result is not as specified, replace the cooler thermistor (solar sensor).

  2. Click here

    INSPECT COOLER THERMISTOR (SOLAR SENSOR) (for RHD)


    1. A01IOBIE03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I1-2 (TSP) - I1-1 (S5) Solar sensor covered with a cloth ∞ Ω
      I1-2 (TSP) - I1-1 (S5) Solar sensor exposed to electric light Except ∞ Ω
      I1-3 (TSD) - I1-1 (S5) Solar sensor covered with a cloth ∞ Ω
      I1-3 (TSD) - I1-1 (S5) Solar sensor exposed to electric light Except ∞ Ω
      Table 2. Text in Illustration
      *1

      Component without harness connected

      (Cooler Thermistor [Solar Sensor])

      Tip:

      Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).

      If the result is not as specified, replace the cooler thermistor (solar sensor).