COMBUSTION TYPE POWER HEATER SYSTEM, Diagnostic DTC:050, 052, 054, 056

DTC Code DTC Name
050 Detection of No Ignition
052 Safety Time Exceeded
054 High Setting of Flame Cutout
056 Low Setting of Flame Cutout

DESCRIPTION

DTC Code DTC Detection Condition Trouble Area
050 The ECU is locked as a result of 10 successive heater ignition failures (DTC 052 is detected 10 times in a row).
  • Fuel pipe

  • Air duct

  • No. 1 exhaust pipe sub-assembly

  • No. 2 exhaust pipe sub-assembly

  • Fuel filter assembly

  • Heater pump assembly

  • Heater assembly (ECU)

052 A heater ignition failure is detected.
  • Fuel pipe

  • Air duct

  • No. 1 exhaust pipe sub-assembly

  • No. 2 exhaust pipe sub-assembly

  • Fuel filter assembly

  • Heater pump assembly

  • Heater assembly (ECU)

054 Combustion ends abnormally (high output operation).
  • Fuel pipe

  • Air duct

  • No. 1 exhaust pipe sub-assembly

  • No. 2 exhaust pipe sub-assembly

  • Fuel filter assembly

  • Heater pump assembly

  • Heater assembly (ECU)

056 Combustion ends abnormally (low output operation).
  • Fuel pipe

  • Air duct

  • No. 1 exhaust pipe sub-assembly

  • No. 2 exhaust pipe sub-assembly

  • Fuel filter assembly

  • Heater pump assembly

  • Heater assembly (ECU)

INSPECTION PROCEDURE

CAUTION:


  • In some cases, the heater assembly, air duct and exhaust pipes are extremely hot. When performing the inspection, wear protective gloves and do not touch these parts with bare hands.

  • When performing the inspection, wear a face mask to prevent direct inhalation of exhaust gas.

Tech Tips


  • Output of DTC 050 indicates that the heater assembly has been locked by the ECU and cannot be operated. Clear the DTCs by pressing the memory clear buttons on the DTC tester to unlock the ECU Click here.

  • Before performing the following inspections, attempt to restart the heater assembly. If the heater assembly is successfully started, confirm that neither DTC 054 nor DTC 056 is output. If neither DTC 054 nor 056 is output, stop troubleshooting because it can be concluded that the system has returned to normal.

PROCEDURE


  1. INSPECT FUEL PIPE


    1. Check that there is no fuel leakage between the heater pump assembly and heater assembly.

      OK
      There is no problem in the fuel pipe.

    NG
    OK
  2. INSPECT AIR DUCT


    1. Perform the following checks of the air duct.


      • The air duct is not clogged with foreign matter.

      • Air intake is normal.

      • The air duct is correctly installed to the heater assembly.

      • There are no defects that would cause air to leak from the intake air duct.

      OK
      There is no problem with the air duct.

    NG
    OK
  3. INSPECT EXHAUST PIPE SUB-ASSEMBLY


    1. Check that hot exhaust gas is coming out of the exhaust pipes.

      CAUTION:


      • The exhaust pipes and muffler are extremely hot. Wear protective gloves and do not touch these parts with bare hands.

      • When performing the inspection, wear a face mask to prevent direct inhalation of exhaust gas.

      Result
      Result Proceed to
      There is no problem with the exhaust pipes. A
      There is a problem with the exhaust pipe (No. 1 exhaust pipe sub-assembly). B
      There is a problem with the exhaust pipe (No. 2 exhaust pipe sub-assembly). C

    B
    C
    A
  4. INSPECT HEATER PUMP ASSEMBLY


    1. A01ITQWE07

      Remove the heater pump assembly with the fuel hose still connected Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (B2) - 2 (E2) Always 9 to 12 Ω
    3. Apply battery voltage to the heater pump assembly and check the pressure of the hose by hand.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1

      Battery negative (-) → Terminal 2

      Pressure is applied to the hose

      Note


      • This inspection must be done quickly (within 10 seconds) to prevent damage to the heater pump assembly.

      • Always switch the voltage on and off on the battery side, not the heater pump assembly side.

      • Keep the heater pump assembly as far away from the battery as possible.


    NG
    OK
  5. REPLACE FUEL FILTER ASSEMBLY


    1. for 1AD-FTV:


      1. Replace the fuel filter assembly with a new one Click here.

    2. for 2AD-FHV:


      1. Replace the fuel filter assembly with a new one Click here.

    3. Check that the system returns to normal.

      OK
      Heater assembly ignition begins normally and the heater assembly starts operating.

    NG
    OK