Click here

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) Back-up Power Source Circuit

Click here
Click here Click here
DTC Code DTC Name
  Back-up Power Source Circuit
Click here

DESCRIPTION

The back-up power source circuit for the air conditioning amplifier assembly is shown below. Power is supplied even after the ignition switch is turned off and is used for diagnostic trouble code memory, etc.

Click here

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

Note:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Click here

PROCEDURE


  1. Click here

    CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY)


    1. A01IUPJE43

      Disconnect the H10 amplifier connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      H10-1 (B) - Body ground Always 11 to 14 V
      Table 1. Text in Illustration
      *1

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)


  2. Click here

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here

  3. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR