DESCRIPTION
When the engine is started, the generator assembly turns on and a pulsed voltage signal is generated.
This signal is used by the air conditioning amplifier assembly.
The signal expressing the amount of output from the generator assembly is one element of PTC heater control.
INSPECTION PROCEDURE
PROCEDURE
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - GENERATOR)
Disconnect the H46 amplifier connector.
Disconnect the C26 generator connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| *1 | Rear view of wire harness connector (to Air Conditioning Amplifier Assembly) |
| *2 | Front view of wire harness connector (to Generator Assembly) |
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR