DESCRIPTION
The cooler thermistor (solar sensor), which is installed on the upper side of the instrument panel, detects sunlight and controls the air conditioning in auto mode. The output current from the solar sensor varies according to the amount of sunlight. When the amount of sunlight increases, the output current increases. As the amount of sunlight decreases, the output current decreases. The air conditioning amplifier assembly detects the output current from the solar sensor.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B14A3 | An open or short in the passenger side solar sensor circuit. |
|
If the check is performed in a dark place, DTC B14A2 or B14A3 (solar sensor circuit abnormal) may be stored even though the system is normal.
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (SOLAR SENSOR)
Use the Data List to check if the solar sensor is functioning properly.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Solar Sensor (P Side) | Solar sensor / Min.: 0, Max.: 255 | Passenger side solar sensor voltage increases as brightness increases | Open in the circuit: 0. Short in the circuit: 255. |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to Problem Symptoms Table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
CHECK HARNESS AND CONNECTOR (SOLAR SENSOR - AIR CONDITIONING AMPLIFIER)
Disconnect the I1 sensor connector.
Disconnect the H46 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
|
| *1 | for LHD |
| *2 | for RHD |
| *3 | Front view of wire harness connector (to Solar Sensor) |
| *4 | Rear view of wire harness connector (to Air Conditioning Amplifier Assembly) |
INSPECT COOLER THERMISTOR (SOLAR SENSOR)
*1: for LHD
*2: for RHD
Remove the solar sensor (Click here).
Measure the resistance of the sensor.
Connect the positive (+) lead of the ohmmeter to terminal 1 and the negative (-) lead to terminal 2*1 or 3*2 of the solar sensor.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|||||||||
|
| *1 | for LHD |
| *2 | for RHD |
The connection procedure for using a digital tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2*1 or 3*2 and the negative (-) lead to terminal 1 of the solar sensor.
As the inspection light is moved away from the sensor, the voltage decreases.
Use an incandescent light for the inspection. Position it about 30 cm (11.8 in.) from the solar sensor.
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE COOLER THERMISTOR (SOLAR SENSOR)Click here
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here