DESCRIPTION
The cooler thermistor (ambient temperature sensor) is installed in the front part of the condenser assembly with receiver to detect the ambient temperature and control the air conditioning auto mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The combination meter assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor). The combination meter assembly sends the signal to the air conditioning amplifier assembly via CAN communication.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1412/12 | An open or short in the ambient temperature sensor circuit. |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
CHECK CAN COMMUNICATION SYSTEM
Use the intelligent tester to check if the CAN communication system is functioning normally.
| OK |
|---|
| CAN DTC is not output. |
| NG |
|
GO TO CAN COMMUNICATION SYSTEM Click here |
| OK |
|
READ VALUE USING INTELLIGENT TESTER
Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temp Sensor | Ambient temperature sensor / Min: -23.3°C (-9.94°F) Max: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Open in the circuit: -23.3°C (-9.94°F). Short in the circuit: 65.95°C (150.71°F). |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to Problem Symptoms Table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
| B |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| C |
|
INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) Click here |
| A |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
for Diesel:
Remove the ambient temperature sensor Click here.
for ZR Series Engine:
Remove the ambient temperature sensor Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (refer to the graph).
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for Diesel) | B |
| NG (for ZR Series Engine) | C |
| B |
|
REPLACE COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) Click here |
| C |
|
REPLACE COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) Click here |
| A |
|
CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - COMBINATION METER)
| *1 | Front view of wire harness connector (to Ambient Temperature Sensor) |
| *2 | Rear view of wire harness connector (to Combination Meter Assembly) |
Disconnect the A25 sensor connector.
Disconnect the H62 meter connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here