AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) DATA LIST / ACTIVE TEST


  1. DATA LIST

    Tech Tips

    Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus:


      • Body / Air Conditioner / Data List.

      • Powertrain / Engine and ECT / Data List.

    5. According to the display on the intelligent tester, read the Data List.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor

      Room temperature sensor /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual room temperature for front seat displayed

      Open in the circuit: -6.5°C (20.3°F).

      Short in the circuit: 57.25°C (135.05°F).

      Ambient Temp Sensor

      Ambient temperature sensor /

      Min.: -23.3°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed

      Open in the circuit: -23.3°C (-9.94°F).

      Short in the circuit: 65.95°C (150.71°F).

      Adjusted Ambient Temp

      Adjusted ambient temperature /

      Min.: -30.8°C (-23.44°F)

      Max.: 50.8°C (123.44°F)

      Adjusted ambient temperature displayed -
      Evaporator Fin Thermistor

      No. 1 cooler thermistor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed

      Open in the circuit: -29.7°C (-21.46°F).

      Short in the circuit: 59.55°C (139.19°F).

      Evaporator Target Temp

      Target evaporator temperature /

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Target evaporator temperature displayed -
      Solar Sensor (D Side) Solar sensor / Min.: 0, Max.: 255 Driver side solar sensor voltage increases as brightness increases

      Open in the circuit: 0.

      Short in the circuit: 255.

      Solar Sensor (P Side) Solar sensor / Min.: 0, Max.: 255 Passenger side solar sensor voltage increases as brightness increases

      Open in the circuit: 0.

      Short in the circuit: 255.

      Engine Coolant Temp

      Engine coolant temperature /

      Min.: 1.3°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Set Temperature (D Side)

      Driver side set temperature /

      MAX COLD: 0°C (32°F)

      MAX HOT: 30°C (86°F)

      Driver side set temperature displayed -
      Set Temperature (P Side)

      Passenger side set temperature /

      MAX COLD: 0°C (32°F)

      MAX HOT: 30°C (86°F)

      Passenger side set temperature displayed -
      Blower Motor Speed Level Blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31 Increases in range between 0 and 31 as blower with fan motor sub-assembly speed increases -
      Regulator Pressure Sensor

      Refrigerant pressure sensor /

      Min.: -0.4566 MPa

      Max.: 3.2943 MPa

      Actual refrigerant pressure displayed -
      Regulator Control Current Compressor assembly with pulley / Min.: 0, Max.: 0.997 Value changes between 0 A and 0.997 A in accordance with compressor assembly with pulley operation -
      Air Mix Servo Targ Pulse (D) Air mix control servo motor (for driver side) target pulse / Min.: 0, Max.: 255

      for LHD:


      • 92 (pulse): MAX COOL

      • 5 (pulse): MAX HOT

      for RHD:


      • 6 (pulse): MAX COOL

      • 93 (pulse): MAX HOT

      -
      Air Mix Servo Actual Pulse (D) Air mix control servo motor (for driver side) actual pulse / Min.: 0, Max.: 255

      for LHD:


      • 92 (pulse): MAX COOL

      • 5 (pulse): MAX HOT

      for RHD:


      • 6 (pulse): MAX COOL

      • 93 (pulse): MAX HOT

      -
      Air Mix Servo Targ Pulse (P) Air mix control servo motor (for front passenger side) target pulse / Min.: 0, Max.: 255

      for LHD:


      • 6 (pulse): MAX COOL

      • 93 (pulse): MAX HOT

      for RHD:


      • 92 (pulse): MAX COOL

      • 5 (pulse): MAX HOT

      -
      Air Mix Servo Actual Pulse (P) Air mix control servo motor (for front passenger side) actual pulse / Min.: 0, Max.: 255

      for LHD:


      • 6 (pulse): MAX COOL

      • 93 (pulse): MAX HOT

      for RHD:


      • 92 (pulse): MAX COOL

      • 5 (pulse): MAX HOT

      -
      Air Outlet Servo Pulse (D) Air outlet control servo motor target pulse / Min.: 0, Max.: 255

      47 (pulse): FACE

      37 (pulse): B/L

      18 (pulse): FOOT

      9 (pulse): F/D

      5 (pulse): DEF

      -
      Air Outlet Servo Actu Pulse (D) Air outlet control servo motor actual pulse / Min.: 0, Max.: 255

      47 (pulse): FACE

      37 (pulse): B/L

      18 (pulse): FOOT

      9 (pulse): F/D

      5 (pulse): DEF

      -
      Air Inlet Damper Targ Pulse Damper servo sub-assembly target pulse / Min.: 0, Max.: 255

      for LHD:


      • 19 (pulse): Recirculation

      • 7 (pulse): Fresh

      for RHD:


      • 7 (pulse): Recirculation

      • 25 (pulse): Fresh

      -
      Air Inlet Damper Actual Pulse Damper servo sub-assembly actual pulse / Min.: 0, Max.: 255

      for LHD:


      • 19 (pulse): Recirculation

      • 7 (pulse): Fresh

      for RHD:


      • 7 (pulse): Recirculation

      • 25 (pulse): Fresh

      -
      Electric Heater Count Electric (PTC) heater count / Min.: 0, Max.: 3 Actual number of the heater elements to be heated is displayed w/ PTC Heater
      Electric Heater Active Count Electric (PTC) heater actual count / Min.: 0, Max.: 3 Actual number of the heater elements to be heated is displayed w/ PTC Heater
      Shift Set Temperature Set temperature shift / 2C incr, 1C incr, Normal, 1C decr or 2C decr Customized value displayed -
      Air Inlet Mode Air inlet mode / Auto or Manual Customized value displayed -
      Compressor Mode Compressor mode / Auto or Manual Customized value displayed -
      Evaporator Control Evaporator control / Auto or Manual Customized value displayed -
      Fan speed increment control Fan speed increment control / Slow, Normal, Fast Customized value displayed -
      Foot/DEF Auto Mode Foot/Def auto mode / ON or OFF Customized value displayed -
      Foot/DEF Auto Blow Up Foot/Def auto blower level function / ON or OFF Customized value displayed -
      A/C Cutoff Signal Air conditioning control cutoff signal / OFF or ON

      OFF: Air conditioning control permitted

      ON: Air conditioning control not permitted

      -
      Refrigerant Gas Type Refrigerant gas type / R134a or 1234yf Refrigerant gas type displayed -
      Blower Operation Setting (Stop&Start) Blower level to be 1, when Stop and Start control operate / Blower off or Blower Level1 Customized value displayed -
      Outside Air Mode Auto Switch Function Switches ON / OFF the function to switch the suction opening to the outside air mode automatically when the ignition switch is turned off / ON or OFF Customized value displayed -
      Number of Trouble Codes Number of trouble codes / Min.: 0, Max.: 255 Number of DTCs displayed -
      Engine and ECT
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      A/C Signal A/C signal / ON or OFF

      ON: A/C switch on

      OFF: A/C switch off

      -
  2. ACTIVE TEST

    Tech Tips

    Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Active Test.

    5. According to the display on the intelligent tester, perform the Active Test.

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower with fan motor sub-assembly Min.: 0, Max.: 31 -
      Magnetic Clutch Relay Magnet clutch relay operation ON or OFF -
      Defogger Relay (Rear) Rear window defogger relay operation ON or OFF -
      Heater Active Level* Heater level Min.: 0, Max.: 3 -
      Air Mix Servo Targ Pulse (D) Air mix control servo motor (for driver side) pulse Min.: 0, Max.: 255 -
      Air Mix Servo Targ Pulse (P) Air mix control servo motor (for front passenger side) pulse Min.: 0, Max.: 255 -
      Air Outlet Servo Pulse (D) Air outlet control servo motor pulse Min.: 0, Max.: 255 -
      Air Inlet Damper Targ Pulse Damper servo sub-assembly target pulse Min.: 0, Max.: 255 -

      • *: w/ PTC Heater